Fischer Panda FPVG0307 – FP Generator 15000 PVK-UK, KW/kVA 12.7 / 15.0, 3000 RPM, 3 Cyl., 1606 x 522 x 630

$31,918.00

Description

Fischer Panda 15000 PVK-UK Generator for Sale – FPVG0307

The Fischer Panda 15000 PVK-UK, listed under reference FPVG0307, is a three-cylinder diesel vehicle generator with a published nominal output of 12.7 kW / 15.0 kVA at a fixed 3,000 RPM. Fischer Panda’s corresponding manufacturer reference is the Panda 15000x PVK-UK.

Its integrated radiator brings the cooling equipment into the externally mounted generator assembly. Contact Marine Inboard Specialists for a quotation covering the electrical configuration, controls and installation equipment required for your project.

The reference capsule measures 1,606 × 522 × 630 mm, excluding fittings. Confirm the complete installation envelope and supplied manufacturer article number before ordering.

Request Price & Availability | Download Manufacturer Datasheet

Fixed-Speed Power with a Kubota D902 Engine

The 15000x PVK-UK belongs to Fischer Panda’s xSeries Compact Power range. The documented configuration uses a Kubota D902 diesel engine, with three cylinders, 898 cm³ displacement and a 12 V starting system. Fischer Panda identifies xControl / fpControl equipment for this reference.

For a specialist vehicle, mobile workshop or expedition project, start with the equipment that must operate together. Battery chargers, refrigeration, air conditioning, heaters and tools create different combinations of running load and starting demand.

Provide an equipment schedule and your expected daily operating hours. These details help establish whether this generator’s output and operating limits match the intended application.

External Installation with an Integrated Radiator

PVK-UK identifies Fischer Panda’s external vehicle installation arrangement with an integrated radiator and cooling system. The manufacturer describes a metal enclosure with a heavy-duty cover, mounting provisions and a wide access hatch. This format removes the need to locate a separate remote radiator.

The complete assembly still needs suitable chassis space, airflow, structural support, ground clearance and maintenance access. Its integrated cooling arrangement makes the generator’s full length particularly relevant when measuring the proposed mounting position.

Fischer Panda distinguishes PVK-UK from PVK-U, which requires a separate radiator, and PVMV-N, intended for internal vehicle installation with remote cooling. Specify a boat application explicitly so the appropriate marine generator configuration can be assessed.

Fischer Panda FPVG0307 Technical Specifications

The figures below describe the manufacturer’s 230 V, single-phase reference, article 0032665. Match this reference to the actual assembly offered under FPVG0307.

Specification Published reference
Product listing reference FPVG0307
Manufacturer reference model Panda 15000x PVK-UK
Reference manufacturer article 0032665
Generator family xSeries – Compact Power
Application External vehicle chassis installation
Nominal electrical output 12.7 kW / 15.0 kVA
Reference AC supply 230 V / 50 Hz / single-phase
Engine operating speed Fixed 3,000 RPM
Diesel engine Kubota D902
Cylinders / displacement 3 / 898 cm³
Starting system 12 V electric
Published control system xControl / fpControl
Capsule designation MPL 4DS
Capsule size, L × W × H 1,606 × 522 × 630 mm, excluding fittings
Weight including capsule Approximately 430 kg
Published acoustic reference 54 dB(A) at 7 metres
Cooling arrangement Integrated radiator
Permitted sustained load Confirm for the supplied assembly and operating conditions

Source: Fischer Panda 15000x PVK-UK manufacturer specifications and manufacturer datasheet.

The FPVG0307 listing title does not identify voltage or phase. Have the quotation state both. If your installation requires three-phase power or 60 Hz, include that requirement at the enquiry stage so the correct configuration can be established.

Understanding 12.7 kW and 15.0 kVA

kW measures real electrical power; kVA measures apparent power. The 15000 model name and 15.0 kVA figure should not be interpreted as a 15 kW real-power rating.

Fischer Panda’s vehicle brochure explains that the 0.85 factor used for this asynchronous range’s kVA figure relates to short starting performance for inductive consumers. Request the applicable sustained-output and starting-performance information for the offered generator.

For example, a charger drawing 4.0 kW from the AC supply, a 2.0 kW heater and 3.0 kW of other equipment total 9.0 kW before auxiliary consumption and motor starting. This illustrative calculation helps prepare an enquiry; starting current, power factor and permissible sustained load still need assessment.

The manufacturer’s reference performance conditions are 20°C and 100 metres above sea level. Provide the expected operating temperature and altitude when requesting a rating review.

Three Checks Before Replacing Your Generator

Match the Electrical System

Send the existing generator’s model, serial number, rated output, voltage, frequency and phase configuration. Include simultaneous loads, daily running hours and starting-current information for the largest motors where available.

Have your installer assess distribution protection, shore-power changeover, charger integration and compatibility with existing controls. Identify any panels, harnesses or electrical equipment you intend to retain.

Match the Chassis Space and Mountings

Measure the available mounting envelope, ground clearance and service access. The reference package is approximately 1.6 metres long, so check the complete chassis position and access for installation or removal.

Fischer Panda publishes a 15000x PVK-UK reference drawing. Obtain the revision applicable to the offered assembly before fabricating brackets or modifying the vehicle.

Allow additional space for fittings, hoses, cables and mountings. Establish total installed weight separately, including fluids, supporting structure and accessories.

Match the Cooling and Exhaust Installation

Show the proposed radiator intake and discharge paths, nearby heat sources, exhaust outlet and access for cleaning. Include photographs of the current cooling arrangement when planning a replacement.

If the previous generator overheated, investigate airflow restrictions, radiator condition and cooling performance before commissioning the replacement. Assess the mounting location alongside the cause of the original failure.

Generator Package and Scope of Supply

Request an itemised quotation identifying the generator assembly, integrated radiator, fan equipment, remote control panel, electrical control or booster equipment, wiring, fuel-system components, mounts and exhaust installation accessories included.

State which existing components you intend to reuse. Similar output figures alone do not establish compatibility with an older control panel, wiring harness or mounting arrangement.

Identify installation labour, chassis modifications, commissioning, documentation and optional maintenance spares separately. This establishes the complete vehicle generator replacement cost and makes quotations easier to compare.

Compare Related Fischer Panda Generators

For lower electrical demand within the integrated-radiator format, compare the Fischer Panda FPVG0306 12000 PVK-UK.

For a similar output class with remote cooling, explore the Fischer Panda FPVG0207 15000 PVK-U, which uses a separate radiator.

Compare output, starting capability, mounting space, cooling layout and package contents together.

Price, Availability, Delivery and Warranty

Request a Fischer Panda 15000 PVK-UK price for your required configuration and destination. The quotation should identify equipment condition, manufacturer reference, supplied accessories, current availability, estimated dispatch date, freight and applicable taxes.

Obtain written warranty terms for the actual generator supplied, including the warrantor, coverage period, operating territory and any registration or commissioning requirements.

For international enquiries, provide the destination country and required emissions or conformity documents. Confirm that the supplied documentation corresponds to the offered engine and generator build.

Frequently Asked Questions

Is the Fischer Panda 15000 PVK-UK a 15 kW generator?

Its published nominal output is 12.7 kW / 15.0 kVA. Use the applicable real-power, starting and sustained-output information when sizing the installation.

Does this generator operate at a fixed speed?

The documented 50 Hz configuration operates at a fixed 3,000 RPM. Fischer Panda’s iSeries models use a separate variable-speed arrangement.

Does PVK-UK include a radiator?

The PVK-UK arrangement incorporates its radiator and cooling system. The installation still requires suitable airflow and service access.

What voltage does the reference model supply?

Manufacturer article 0032665 is documented as 230 V, 50 Hz, single-phase. Confirm the required electrical configuration in the quotation.

What is the published sound level?

Fischer Panda publishes 54 dB(A) at 7 metres. Installed noise depends on mounting, surroundings and operating conditions; this reference figure does not establish the noise level at a particular site.

Can I reuse my existing controls and mounts?

Potentially. Provide their identification details, photographs and measurements so compatibility and condition can be assessed before reuse.

Request Your Fischer Panda FPVG0307 Quotation

For a Fischer Panda 15000 PVK-UK generator for sale, contact Marine Inboard Specialists and quote FPVG0307.

Include the vehicle type, electrical load schedule, required voltage and frequency, daily operating hours, mounting measurements and installation photographs. State how soon you intend to purchase, your required delivery date, and your billing and delivery addresses.

For replacements, attach clear photographs of the existing generator plate, control panel, mounts and cooling installation.

Reviews

There are no reviews yet.


Be the first to review “Fischer Panda FPVG0307 – FP Generator 15000 PVK-UK, KW/kVA 12.7 / 15.0, 3000 RPM, 3 Cyl., 1606 x 522 x 630”