Fischer Panda 10000x PMS Marine Generator for Sale – FPMA3015
The Fischer Panda 10000x PMS, listed under FPMA3015, is a fixed-speed marine diesel generator for onboard AC power. Fischer Panda’s current 230 V, 50 Hz, single-phase reference is rated at 8.0 kW / 9.4 kVA, with a two-cylinder diesel engine operating at 3,000 RPM.
Contact Marine Inboard Specialists for pricing, availability and a quotation matched to your vessel’s electrical supply, load requirements and installation. Establish the exact generator configuration and package contents before ordering.
Request Price & Availability | Download Manufacturer Datasheet
Marine AC Power for Onboard Equipment
The Panda 10000x PMS can be evaluated for loads such as battery charging, refrigeration, air conditioning, pumps and galley equipment. Suitability depends on the equipment running together, motor starting demand and the intended operating schedule.
For example, a hypothetical 6.5 kW running load plus a 2 kW additional load totals 8.5 kW, exceeding the published 8.0 kW nominal output before accounting for starting surges. A generator load schedule helps identify whether a larger unit or managed starting sequence is required.
Include the largest motor’s starting current and any equipment that must remain powered during its start. Running watts alone are insufficient to establish compatibility with an air-conditioning compressor or pump.
Kubota Diesel Engine and Water-Cooled Design
The manufacturer specifies a Kubota Z602 diesel engine, with two cylinders and 599 cm³ displacement. The published starting system is 12 V, and the generator uses a water-cooled marine arrangement with a GFK 3D sound-insulation capsule.
Have the installer assess the complete cooling and exhaust installation against the supplied manual. Include access for servicing, mounting support and the routing of fuel, water and electrical connections.
If replacing a generator that failed after overheating or water ingress, establish the cause and assess the associated vessel systems as part of the replacement plan.
Fischer Panda FPMA3015 Technical Specifications
These are manufacturer reference figures for the published 230 V, 50 Hz Panda 10000x PMS. Confirm the offered unit against its manufacturer article number, identification plate and applicable documentation.
| Specification | Manufacturer reference |
|---|---|
| Model | Fischer Panda 10000x PMS |
| Product listing reference | FPMA3015 |
| Generator family | xSeries Compact Power |
| Nominal electrical output | 8.0 kW / 9.4 kVA |
| Voltage, frequency and phase | 230 V, 50 Hz, single-phase |
| Engine speed | 3,000 RPM |
| Diesel engine | Kubota Z602 |
| Cylinders / displacement | 2 / 599 cm³ |
| Starting system | 12 V |
| Cooling | Water-cooled marine generator |
| Sound capsule | GFK 3D |
| Datasheet capsule dimensions, L × W × H | 650 × 445 × 570 mm, excluding fittings |
| Published weight, including capsule | 175 kg |
| Current product-page control system | fpControl; confirm supplied build |
| Published voltage tolerance | ±3 V |
| Panel, harness, mounts and installation accessories | Identify in the quotation |
Source: Fischer Panda’s product specification and linked manufacturer datasheets.
Specification confirmation: The FPMA3015 catalogue details state 8.0 kW / 10.0 kVA and 705 × 445 × 590 mm. The current manufacturer reference above differs. Request the rating and installation drawing for the actual unit offered before sizing the electrical system or confirming fit.
Understanding kW, kVA and the 10000x Model Name
kW measures real electrical power, while kVA measures apparent power. Fischer Panda publishes a power factor of 0.85 for the current reference. Using the rounded figures, 9.4 kVA × 0.85 ≈ 8.0 kW.
The model name does not establish a 10 kW output, and the supplied listing’s 10 kVA figure should be confirmed against the quoted build’s documents.
For extended daily operation, obtain the manufacturer’s sustained-load guidance, operating limits and maintenance schedule. Include your expected running hours and normal load with the enquiry.
Checking FPMA3015 and Manufacturer References
Use FPMA3015 as the product listing reference when enquiring. The current manufacturer webpage identifies article 0038902, while its linked datasheet identifies 0028283 and describes xControl / fpControl.
Request the actual manufacturer article number and control package in the quotation. These references help identify the supplied configuration; they should not be treated as proof that panels, harnesses or spare parts are interchangeable.
Is This the Right Replacement Marine Generator?
Match the Electrical Supply
Provide the required voltage, frequency and phase arrangement, together with the vessel’s equipment schedule. The specification above describes a 230 V, 50 Hz, single-phase reference.
Have a qualified marine electrician assess the distribution system, protective equipment and shore-power transfer arrangement for the proposed installation.
Match the Installation
Measure the compartment, access opening and mounting footprint. Capsule dimensions exclude fittings and do not define the complete space needed for hoses, cables, mountings or servicing.
Send photographs of the existing generator, mounting base, cooling connections and exhaust route. Confirm the drawing for the offered assembly before planning fabrication or installation.
Match the Controls
Identify the existing panel, harness length, starting battery arrangement and any remote-start or monitoring requirements. Confirm the compatible replacement controls and any additional interface equipment.
For a replacement, provide the current generator model, serial number, operating hours and reason for replacement.
Sound Levels and Fuel Consumption
The manufacturer datasheet reports 52 dB(A) at 7 metres. This is a reference measurement; onboard noise depends on the compartment, mounting and exhaust installation.
Request fuel-consumption information for the exact generator at your anticipated load. Use that information to compare operating costs and plan fuel requirements.
Scope of Supply
The quotation should identify the generator assembly, sound capsule, control panel, harness, connection or control equipment, mounting hardware and supplied manuals.
Establish separately whether the starting battery, cooling and exhaust installation parts, service kit, delivery, installation labour and commissioning are included. Clear package details make the complete marine generator replacement cost easier to compare.
Compare Related Fischer Panda Generators
For a lower-output option, review the Fischer Panda 8000x PMS Marine Generator – FPMA3003.
For a higher-output option, review the Fischer Panda 12000x PMS Marine Generator – FPMA3004.
Browse the wider Fischer Panda Marine Generator range to compare electrical configurations, output, starting capability and installation requirements.
Fischer Panda 10000x Price, Warranty and Delivery
Request a Fischer Panda 10000x PMS price for the configuration and delivery destination you require. The written quotation should identify condition, manufacturer reference, supplied equipment, availability, dispatch estimate, freight charges and applicable taxes.
Obtain warranty terms for the actual unit supplied, including the warrantor, coverage period, territory and registration or commissioning requirements.
For a regulated or classed vessel, state the operating country, flag and required emissions or classification documentation. Confirm the offered configuration using its supply and approval documents.
Frequently Asked Questions
Is the Panda 10000x PMS a 10 kW generator?
Fischer Panda’s current published reference is 8.0 kW / 9.4 kVA. Use the supplied build’s confirmed rating when assessing loads.
Does the engine run at variable speed?
The published 50 Hz 10000x PMS reference operates at 3,000 RPM. It belongs to Fischer Panda’s fixed-speed xSeries range.
Can it run my boat’s air conditioning?
That requires an assessment of compressor starting current, running demand and other simultaneous loads. Provide the equipment details before selecting a generator.
Will it fit the space stated in the FPMA3015 listing?
Obtain the supplied unit’s drawing. The current datasheet gives 650 × 445 × 570 mm for the capsule, excluding fittings, while the listing gives different dimensions.
Can I reuse my existing control panel?
Confirm compatibility against the offered generator’s control system, harness and manufacturer reference before planning reuse.
Does the quotation include installation accessories?
Ask for an itemised package. Cooling and exhaust parts, mounts, controls, installation labour and commissioning should each be identified.
Request Your Fischer Panda 10000x PMS Quotation
For a Fischer Panda FPMA3015 Generator 10000x PMS for sale, contact Marine Inboard Specialists with your vessel type, required electrical supply, load schedule, intended daily running hours and available installation space.
Include how soon you want to purchase, your required delivery date, and your billing and delivery addresses. For a replacement, attach photographs of the current generator plate, control panel and installation.







Reviews
There are no reviews yet.