Fischer Panda FPMA1011 – Generator 4000s.Neo PMS, KW/kVA 3.4/4.0, 3000 RPM, Cyl. 1, 575 x 365 x 550
$8,118.00
- Description
- Reviews (0)
Description
Fischer Panda 4000s.Neo PMS Marine Generator – FPMA1011
The Fischer Panda 4000s.Neo PMS is a compact marine diesel generator with a published nominal output of 3.4 kW / 4.0 kVA. Available through Marine Inboard Specialists under listing reference FPMA1011, the documented configuration supplies 230 V, 50 Hz, single-phase AC power.
With a single-cylinder diesel engine, fixed-speed operation, and sound-insulated enclosure, it can be considered for vessels with modest onboard electrical demand. For a new installation or marine generator replacement, assess the equipment you need to run together and the available installation space.
Fixed-Speed Marine Power at 3,000 RPM
The Panda 4000s.Neo is part of Fischer Panda’s Compact Power range and operates at a fixed 3,000 RPM in the documented 50 Hz configuration. Fischer Panda positions it as an entry-level model for owners with lower onboard power requirements.
This is a useful starting point for assessing battery charging and compatible AC appliances away from shore power. Match the generator’s output to your actual load list, including the starting demand of refrigeration, pumps, and any air-conditioning equipment.
Technical Specifications
The reference figures below follow Fischer Panda’s Panda 4000s.Neo PMS datasheet, manufacturer article 0014669. Match the supplied assembly to its applicable documentation before ordering.
| Specification | Details |
|---|---|
| Product model | Fischer Panda 4000s.Neo PMS |
| Listing reference | FPMA1011 |
| Manufacturer reference in cited datasheet | 0014669 |
| Product range | Compact Power |
| Application | Marine auxiliary electrical generation |
| Published nominal output | 3.4 kW / 4.0 kVA |
| Nominal AC voltage | 230 V |
| Frequency / phase | 50 Hz / single-phase |
| Engine speed | Fixed, 3,000 RPM |
| Fuel | Diesel |
| Engine manufacturer / model | Fischer Panda / FPE 320 |
| Cylinders / displacement | One cylinder / 309 cm³ |
| Starting system | 12 V electric |
| Cooling | Water-cooled marine generating set |
| Published voltage tolerance | ±3 V |
| Published power factor | 0.85 |
| Sound-insulation capsule | GFK 3D |
| Reference datasheet dimensions, excluding fittings | 580 × 370 × 545 mm |
| Published generator weight with capsule | 97 kg |
Download the Fischer Panda 4000s.Neo PMS datasheet.
The manufacturer’s dimensional documents describe different enclosure envelopes. Obtain the drawing for the actual assembly offered before using dimensions for mounting, compartment access, or service planning.
Understanding 3.4 kW and 4.0 kVA
The published 3.4 kW rating describes real electrical power, while 4.0 kVA describes apparent power. The two figures correspond to the stated 0.85 power factor.
Use both limits when assessing your electrical loads. The model name and kVA figure should not be treated as a 4 kW real-power rating.
For extended running, obtain the applicable continuous-output rating and operating conditions for the supplied unit. Starting demand and sustained demand must both fit the intended installation.
Is the 4000s.Neo Right for Your Boat?
Prepare a list of simultaneous loads, including battery chargers, refrigeration, pumps, lighting circuits, and occasional appliances. For equipment normally supplied through the boat’s DC system, include the associated charger’s AC input in the assessment.
A small generator benefits from deliberate appliance scheduling. For example, a hypothetical 1.6 kW running load plus a 2.0 kW kettle totals 3.6 kW, exceeding the published 3.4 kW nominal output before allowing for motor starts.
If you need air conditioning, provide the compressor’s running and starting specifications. Your installer can assess whether the combination fits the generator or requires a larger model.
Match the Electrical System, Space and Installation
Match the Electrical System
For a replacement enquiry, provide the current generator’s model, serial number, output, voltage, frequency, and phase. Have your marine electrician assess wiring, electrical protection, shore-power changeover, earthing, and any inverter/charger integration.
Confirm the voltage and frequency required by your appliances. Identify any automatic-start interface needed as part of the control package.
Match the Available Space
Allow room for connections, enclosure removal, filters, cooling components, and routine servicing. Check the route into the machinery compartment as well as the final mounting position.
Use a dimensioned drawing for the offered unit and include any separately mounted control equipment in the layout. Similar published dimensions alone do not establish a direct replacement fit.
Match the Cooling and Exhaust
Have your installer review seawater supply, freshwater cooling, wet-exhaust routing, waterlock placement, and the generator’s position relative to the waterline. For a sailing installation, the assessment should also consider vessel heel.
Fischer Panda’s 4000s.Neo installation and operating manual covers these systems. Use the manual applicable to the supplied build.
If the previous generator failed after overheating or water entry, resolve the cause before fitting its replacement.
Sound-Insulated Onboard Power
The enclosure helps control machinery noise. Cabin sound also depends on mounting, structural vibration, exhaust routing, and proximity to accommodation.
For a quiet marine generator installation, assess the complete arrangement while maintaining the ventilation and service access required by the supplied equipment.
Generator Package and Scope of Supply
Request an itemized quotation identifying the generating set, enclosure, remote control panel, connecting cables, electrical control components, mounting equipment, and documentation included.
The manufacturer’s manual describes AC control arrangements that vary by generator configuration. Establish whether any control box is mounted separately and what space and connections it requires.
Specify any fuel pump, cooling and exhaust installation parts, starting battery, additional cables, or service spares needed. Identify installation labour and commissioning separately to compare the complete marine generator replacement cost.
Compare Related Fischer Panda Generators
For a variable-speed alternative, compare the Fischer Panda 5000i.Neo PMS – FPMA1012. For greater electrical capacity, explore the Fischer Panda 8000i PMS – FPMA1002.
Browse our Fischer Panda marine generator range to compare capacity, operating speed, installation requirements, and package scope.
Fischer Panda 4000s.Neo PMS Price, Delivery and Warranty
Request a Fischer Panda 4000s.Neo PMS price for your required package and destination. The written quotation should identify the exact model and condition, included equipment, current availability, dispatch estimate, freight charges, and applicable taxes.
Obtain the warranty terms for the generator supplied, including the warrantor, coverage period, territory, registration, and installation-approval or commissioning requirements.
Frequently Asked Questions
Is the Panda 4000s.Neo a 4 kW generator?
The cited datasheet specifies 3.4 kW / 4.0 kVA nominal output. The ratings describe real and apparent electrical power respectively.
Is it a variable-speed generator?
The documented 50 Hz version operates at a fixed 3,000 RPM. The variable-speed 5000i.Neo is a separate model.
What engine does the reference version use?
The manufacturer datasheet specifies a single-cylinder Fischer Panda FPE 320 diesel engine, with 309 cm³ displacement.
Can it run my boat’s air conditioning?
That depends on compressor starting current, running demand, and other simultaneous loads. Provide the equipment specifications for assessment.
Can it replace my existing small marine generator?
Potentially. Output, electrical configuration, mounting, dimensions, cooling, exhaust, and controls need to be matched to the installation.
Does the quotation include installation accessories?
The itemized quotation establishes what is supplied. Specify the controls, mounts, fuel-system components, cooling parts, and exhaust equipment needed.
Request Your Fischer Panda 4000s.Neo PMS Quotation
For a Fischer Panda 4000s.Neo marine generator for sale, contact Marine Inboard Specialists and quote FPMA1011. Include your vessel type, electrical load list, required voltage and frequency, intended operating hours, and package requirements. For a replacement, attach the existing generator plate and compartment photographs. Tell us how soon you want to purchase and provide your billing and delivery addresses for an official quotation.







Reviews
There are no reviews yet.