Fischer Panda FPMA1008 – Generator 25i – 400V PMS, KW/kVA 20.0 / 25.0, 2200-2800 RPM, Cyl. 3, 840 x 563 x 664
$31,998.00
- Description
- Reviews (0)
Description
Fischer Panda 25i 400V PMS Marine Generator – FPMA1008
The Fischer Panda 25i 400V PMS is a three-phase marine diesel generator with a published nominal output of 20.0 kW / 25.0 kVA. Available through Marine Inboard Specialists under listing reference FPMA1008, the documented configuration supplies 400 V, 50 Hz AC power.
For vessels with compatible three-phase machinery and substantial onboard electrical demand, the 25i offers variable-speed generation in a sound-insulated enclosure. Assess it against your pumps, compressors, watermakers, air conditioning, and accommodation loads, together with the vessel’s electrical distribution and operating schedule.
Variable-Speed Generation with Inverter Regulation
The Panda 25i belongs to Fischer Panda’s iSeries marine inverter generator range. Engine speed responds to electrical demand, while the matched inverter regulates the AC output. This allows speed to change while maintaining the specified supply frequency.
The generating set, three-phase inverter, and controls form a matched system. Include the complete arrangement when comparing quotations and planning the installation.
Technical Specifications
The reference figures below follow Fischer Panda’s Panda 25i – 400 V PMS datasheet, manufacturer article 0005059. Identify the exact generating set and inverter in the quotation.
| Specification | Details |
|---|---|
| Product model | Fischer Panda 25i – 400 V PMS |
| Listing reference | FPMA1008 |
| Manufacturer reference in cited datasheet | 0005059 |
| Application | Marine auxiliary electrical generation |
| Published nominal output | 20.0 kW / 25.0 kVA |
| Nominal AC voltage | 400 V |
| Frequency / phase | 50 Hz / three-phase |
| Published reference engine speed | Variable, 2,400–3,000 RPM |
| Fuel | Diesel |
| Engine | Kubota V1505 |
| Cylinders / displacement | Four cylinders / 1,498 cm³ |
| Starting system | 12 V electric |
| Control system | Fischer Panda iControl |
| Published voltage tolerance | ±3% |
| Published power factor | 0.80 |
| Sound-insulation capsule | GFK 3D |
| Datasheet capsule dimensions, excluding fittings | 840 × 520 × 664 mm |
| Published generator weight with capsule | 230 kg |
| Published separate inverter weight | 39 kg |
Download the Fischer Panda 25i 400V PMS datasheet.
Figures and equipment can differ between versions. Match the offered unit’s identification to its applicable drawing and documentation before ordering.
Understanding 20 kW, 25 kVA and Phase Loading
The 20 kW rating describes real electrical power, while 25 kVA describes apparent power. Both limits matter when assessing the vessel’s running and motor-starting loads.
With a 400V three-phase marine generator, the load on each phase also needs assessment. Do not assume the full generator rating is available to one single-phase appliance.
A vessel may have a moderate total demand while concentrating several single-phase appliances on one phase. Your marine electrician should review phase currents, permitted imbalance, and load distribution against the supplied inverter’s limits.
If the vessel also needs 230 V appliances, establish the available phase-to-neutral supply, neutral arrangement, and allowable loading. Include those appliances in the same load assessment as the three-phase equipment.
Sustained Demand and Operating Hours
Fischer Panda’s Panda 25i system manual, revision R04.4 dated 25 July 2025, recommends limiting loads sustained over several hours to 80% of nominal output for engine longevity. For the documented 20 kW model, this corresponds to 16 kW, calculated as 20 × 0.80. Use this as operating guidance alongside the supplied unit’s applicable rating and installation conditions.
The manual also addresses prolonged light-load operation. Compare normal demand, peak demand, and daily running hours when deciding whether the 25i is correctly sized.
For a quotation, provide equipment ratings, motor-starting details, and a list of loads that must operate together. Include planned additions to the vessel so future demand can be considered.
Match the Electrical System, Space and Installation
Match the Electrical System
For a replacement, provide the existing generator’s model, serial number, rated output, voltage, frequency, and phase. Have your installer assess switchgear, cables, electrical protection, shore-power changeover, earthing, and any inverter/charger integration.
Confirm motor phase sequence and the compatibility of the vessel’s controls during installation and commissioning. A similar overall power rating does not establish electrical compatibility.
Match the Available Space
Allow room for the generating set, separate inverter, connections, enclosure removal, and servicing. Check the route into the machinery compartment, lifting arrangements, mounting structure, and installed weight.
The manufacturer’s Panda 25i 400V capsule drawing shows the documented assembly and connection layout. Obtain the drawing applicable to the unit offered.
The sound enclosure helps control machinery noise. Mounting, structural vibration, exhaust routing, and proximity to accommodation also affect the sound experienced onboard.
Match the Cooling, Exhaust and Controls
Have your installer review seawater supply, freshwater cooling, wet-exhaust routing, waterlock placement, and inverter cooling requirements. Identify the matched control panel, connecting cables, and any automatic-start interface needed.
Fischer Panda’s Panda 25i installation and operating manual covers the generating set and associated systems. Use documentation applicable to the supplied build.
Generator Package and Scope of Supply
Request an itemized quotation identifying the generating set, sound enclosure, matched three-phase inverter, control panel, connecting cables, fuel pump, mounting equipment, and documentation included.
Specify cooling and exhaust installation parts, additional cable lengths, starting battery, and service spares required. Identify installation labour and commissioning separately to compare the complete marine generator installation cost.
For a replacement project, send photographs of the generator plate, compartment, mounting points, cooling connections, and exhaust. Resolve any cause of previous overheating or water entry before fitting the replacement.
Compare Related Fischer Panda Generators
For lower three-phase demand, compare the Fischer Panda 15000i 400V PMS – FPMA1004-3F. If your vessel requires single-phase power, explore the Fischer Panda 25i 230V PMS – FPMA1007.
Browse our Fischer Panda marine generator range to compare capacity, phase configuration, installation requirements, and package scope.
Fischer Panda 25i 400V PMS Price, Delivery and Warranty
Request a Fischer Panda 25i 400V PMS price for your required package and destination. The written quotation should identify the exact model and condition, included equipment, current availability, dispatch estimate, freight charges, and applicable taxes.
Obtain the warranty terms for the actual generator supplied, including the warrantor, coverage period, territory, registration, and commissioning requirements. Include the operating country and any required emissions or classification documentation with your enquiry.
Frequently Asked Questions
Is the Panda 25i a 25 kW generator?
Its published nominal output is 20.0 kW / 25.0 kVA. Kilowatts and kilovolt-amperes describe different aspects of electrical capacity.
Does this version have three cylinders?
The cited manufacturer datasheet specifies a four-cylinder Kubota V1505 diesel engine, with 1,498 cm³ displacement.
Is the FPMA1008 a three-phase generator?
This description covers the 400 V, 50 Hz, three-phase configuration. The 230 V single-phase model is a separate option.
Can it supply 230 V appliances?
Establish the supplied inverter’s phase-to-neutral output, neutral arrangement, permitted imbalance, and allowable phase loading before connecting them.
Can it deliver 20 kW throughout the day?
Assess sustained demand against the applicable rating and manual. The cited manual recommends an 80% nominal-load target for operation over several hours, equivalent to 16 kW for this reference model.
Does the quoted package include the inverter and installation parts?
The itemized quotation establishes the scope. Request the matched three-phase inverter and specify the installation accessories required.
Request Your Fischer Panda 25i 400V PMS Quotation
For a Fischer Panda 25i 400V marine generator for sale, contact Marine Inboard Specialists and quote FPMA1008. Include your vessel type, electrical load list, voltage, frequency, phase, daily operating hours, and required package. For a replacement, attach the existing generator plate and installation photographs. Tell us how soon you want to purchase and provide your billing and delivery addresses for an official quotation.







Reviews
There are no reviews yet.