Fischer Panda AGT-DC 22000 PMS Marine Generator for Sale – FPMA5010
The Fischer Panda AGT-DC 22000 PMS is a four-cylinder diesel marine generator for direct battery charging and compatible onboard DC power systems. Listed by Marine Inboard Specialists under reference FPMA5010, it is an option for owners, installers and yards planning a battery-based electrical installation or replacing an existing DC generator.
Fischer Panda publishes 21.9 kW continuous output for its AGT-DC 22000-48V PMS, manufacturer article 0032924. This is the reference configuration described below. Your quotation should identify the exact charging voltage, equipment configuration and scope of supply against FPMA5010.
Direct DC Charging for Marine Battery Systems
The AGT-DC range supplies direct current to a compatible battery system. Fischer Panda describes variable engine speed that responds to electrical demand and automatic starting arrangements that can use battery condition to govern generator operation. Specify the required controls and interfaces as part of the installation package.
For a boat using AC appliances, an appropriately sized inverter supplies the required AC voltage and frequency from the DC system. Generator capacity, battery charge acceptance and inverter ratings must therefore be assessed together.
The catalogue notation “21.9/x kW/kVA” should be understood as a DC application. The published continuous electrical output is 21.9 kW; the listing does not establish an AC kVA rating or a direct 230V appliance supply.
Technical Specifications
These figures describe Fischer Panda’s published AGT-DC 22000-48V PMS reference configuration. Sources are the manufacturer’s model datasheet and the 2026 marine generator brochure.
| Specification | Published reference |
|---|---|
| Product family | Fischer Panda AGT-DC 22000 PMS |
| Marine Inboard Specialists reference | FPMA5010 |
| Manufacturer reference model | AGT-DC 22000-48V PMS |
| Manufacturer article number | 0032924 |
| Application | Marine DC battery charging |
| Continuous electrical output | 21.9 kW |
| Nominal charging-system voltage | 48V for the reference model |
| Engine speed | 2,400–3,000 RPM, brochure reference |
| Fuel | Diesel |
| Engine manufacturer / model | Kubota V1505T |
| Cylinders | Four |
| Displacement | 1,498 cm³ / 1.498 litres |
| Starter system | 12V |
| Control system | fpControl |
| Cooling | Water-cooled, two cooling circuits |
| Sound enclosure | GFK capsule; confirm insulation version |
| Approximate capsule dimensions | 960 × 570 × 680 mm, L × W × H, excluding fittings |
| Approximate weight including capsule | 350 kg |
| Published sound level | 55 dB(A) at 7 metres |
| Charging current | Dependent on voltage and configuration |
The 2,400–3,000 RPM range comes from the manufacturer’s brochure; the individual model datasheet leaves engine speed unspecified. Confirm the operating range for the offered assembly. The 12V starter system is separate from the reference model’s nominal 48V charging output.
Is the AGT-DC 22000 Right for Your Boat?
For a marine DC generator replacement or new installation, use three checks: match the battery system, match the electrical demand and match the installation.
Match the Battery System
Provide the battery manufacturer, chemistry, nominal voltage, capacity and permitted charging current. Include the battery management system details and required charging settings.
For lithium installations, have the system designer establish the control interface and the response when the battery management system limits or stops charging. A compatible nominal voltage is only one part of the assessment.
Match the Electrical Demand
Provide your inverter model, continuous and surge ratings, normal simultaneous loads and estimated daily energy use. State whether the generator supports domestic loads, electric propulsion or both.
A generator selected for high sustained demand may be unnecessary for a system serving occasional peaks. Assess expected consumption, available charging time and battery acceptance before deciding how much generating capacity the project needs.
Match the Installation
Compare the mounting arrangement, available space, cable routes, fuel supply, cooling-water installation and exhaust system against the offered assembly’s documents. Include access for servicing and equipment removal.
For a replacement project, provide the existing generator model and serial number, identification-plate photographs and clear installation images. Have your installer assess which existing components can be retained.
Understanding the 21.9 kW Continuous Output
The generator’s output and the power reaching the batteries are different figures. Equipment operating on the same DC system uses part of the available power.
As an illustrative calculation, if the generator delivers 21.9 kW while connected equipment consumes 6.0 kW, approximately 15.9 kW remains before cable and other system losses. Actual charging can be lower because of battery limits, temperature, state of charge and the configured operating conditions.
Obtain the specified charging voltage and continuous-current rating for the offered unit. Dividing output by a nominal battery voltage alone does not establish guaranteed charging current.
Fischer Panda states that AGT-DC output must be limited to the published continuous performance when charging batteries. Base your energy plan on the 21.9 kW continuous reference, subject to the applicable configuration and operating conditions.
Dimensions, Installation Space and Sound Insulation
The FPMA5010 listing gives 980 × 600 × 700 mm. Fischer Panda’s model datasheet and 2026 brochure give 960 × 570 × 680 mm for the reference capsule, excluding fittings. Use the quoted unit’s dimensions and installation drawing to establish fit.
Allow additional room for hoses, cables, mountings, capsule removal and servicing. Fischer Panda provides a reference drawing for article 0032924; your installer should obtain the applicable revision for the assembly supplied.
The model datasheet identifies GFK 3D, while the 2026 brochure lists 4DS insulation for the AGT-DC 22000. The quotation should establish the enclosure and insulation version included. Both publications give a reference sound level of 55 dB(A) at 7 metres. Noise experienced aboard also depends on mounting, structural vibration, exhaust arrangement and generator location.
Generator Package and Scope of Supply
Request an itemized quotation identifying the generator assembly, capsule, fpControl panel, wiring harness, mounting equipment and installation accessories included.
Identify separately the battery bank, inverter, DC protection and isolation, fuel components, cooling-water equipment and exhaust parts required for your project. Include installation labour and commissioning when comparing the complete marine generator replacement cost.
Establish the remote-start arrangement and any interfaces needed for the vessel’s energy-management system. For service parts and manuals, retain the manufacturer article number and generator serial number alongside the FPMA5010 listing reference.
Compare Related Fischer Panda DC Generators
For smaller installations, compare the Fischer Panda AGT-DC 13000 PMS – FPMA5008 and Fischer Panda AGT-DC 11000 PMS – FPMA5007.
Compare continuous DC output, charging voltage, controls, battery acceptance and installed space. Browse our Fischer Panda marine generators to assess other electrical configurations.
Fischer Panda AGT-DC 22000 Price, Delivery and Warranty
Request a Fischer Panda AGT-DC 22000 price for your required configuration and destination. The written quotation should identify the manufacturer article number, output voltage, equipment condition, scope of supply, availability, dispatch estimate, freight charges and applicable taxes.
Obtain the warranty terms for the actual unit, including the warrantor, coverage period, territory and registration or commissioning requirements.
Provide the operating country and any emissions or classification documentation required for the vessel. The manufacturer’s model page lists IMO MARPOL 73/78 for the reference configuration; establish the offered engine’s certification for your destination before purchase.
Frequently Asked Questions
Is the AGT-DC 22000 an AC or DC generator?
It is a DC battery-charging generator. AC appliances require an appropriately specified inverter within the boat’s electrical system.
What is its continuous output?
Fischer Panda publishes 21.9 kW continuous for the AGT-DC 22000-48V PMS reference configuration.
Is FPMA5010 supplied as a 48V generator?
The reference described here is 48V. The listing title omits voltage, so obtain written confirmation of the charging voltage supplied.
Can it charge lithium batteries?
Potentially, with an approved system configuration. Battery charge limits, control interfaces and the response to a battery management system stop request need assessment.
Which dimensions should my installer use?
Use the drawing for the exact unit quoted. The listing gives 980 × 600 × 700 mm, while the manufacturer reference capsule measures 960 × 570 × 680 mm excluding fittings.
Does the package include batteries and an inverter?
The itemized quotation establishes the scope. Specify these components when requesting a complete battery-based power package.
Request Your Fischer Panda AGT-DC 22000 Quotation
For a Fischer Panda AGT-DC 22000 PMS marine generator for sale, contact Marine Inboard Specialists and quote FPMA5010.
Include your vessel details, battery voltage and capacity, battery chemistry, inverter model, expected electrical demand and available installation space. State how soon you want to purchase, your required delivery date, and your billing and delivery addresses. For a replacement, attach photographs of the existing generator plate and installation.







Reviews