Fischer Panda AGT-DC 13000 PMS Marine Generator for Sale – FPMA5008

The Fischer Panda AGT-DC 13000 PMS is a diesel marine generator for direct battery charging and compatible onboard DC electrical systems. Listed by Marine Inboard Specialists under reference FPMA5008, it is an option for battery-based power installations, hybrid projects and replacement DC generator enquiries.

Fischer Panda publishes 12.7 kW continuous output for its AGT-DC 13000-48V PMS, manufacturer article 0032928. This is the reference configuration described below. As the FPMA5008 listing title omits voltage, your quotation should identify the charging voltage and exact assembly supplied.

Direct DC Power for Marine Battery Charging

The AGT-DC range produces direct current for a compatible battery system. Fischer Panda describes variable engine speed that responds to energy demand, with automatic starting arrangements that can use battery condition to govern generator operation. Establish the required controls and battery interfaces when specifying your package.

Where the boat uses AC appliances, a suitable inverter converts power from the DC system into the required AC supply. Generator output, battery capacity and inverter performance therefore need to be assessed together.

For buyers comparing marine diesel generators, the catalogue notation “12.7/x kW/kVA” identifies a DC application. The published electrical output is 12.7 kW continuous; it should not be presented as a 12.7 kVA AC rating.

Technical Specifications

The specifications below refer to Fischer Panda’s published AGT-DC 13000-48V PMS configuration. Sources are the manufacturer’s model datasheet and the 2026 marine generator brochure.

Specification Published reference
Product family Fischer Panda AGT-DC 13000 PMS
Marine Inboard Specialists reference FPMA5008
Manufacturer reference model AGT-DC 13000-48V PMS
Manufacturer article number 0032928
Application Marine DC battery charging
Continuous electrical output 12.7 kW
Nominal charging-system voltage 48V for the reference model
Engine speed 2,400–3,000 RPM, brochure reference
Fuel Diesel
Engine manufacturer / model Kubota D1105
Cylinders Three
Displacement 1,123 cm³ / 1.123 litres
Starter system 12V
Control system fpControl
Cooling Water-cooled, two cooling circuits
Sound enclosure GFK capsule with 3D insulation
Approximate capsule dimensions 760 × 515 × 613 mm, L × W × H, excluding fittings
Approximate weight including capsule 226 kg
Published sound level 55 dB(A) at 7 metres
Charging current Dependent on voltage and configuration

The 2,400–3,000 RPM range appears in the manufacturer’s brochure and matches this listing. The individual model datasheet leaves speed unspecified, so obtain the applicable operating range with the offered unit’s documentation. The reference model uses a 12V starter system, which is separate from its nominal 48V DC charging output.

Is This the Right DC Generator for Your Boat?

Assess the installation through three checks: match the battery bank, match the energy demand and match the installation.

Match the Battery Bank

Provide the battery manufacturer, chemistry, nominal voltage, capacity and maximum permitted charging current. Include the battery management system information and the required charging profile.

For lithium batteries, have the system designer establish how charging limits are communicated and how the generator responds when charging must stop. A nominal voltage match alone does not establish compatibility.

Match the Energy Demand

Provide the inverter make and model, continuous and surge ratings, normal simultaneous loads and estimated daily energy consumption. State whether the system supplies domestic equipment, electric propulsion or both.

The intended operating pattern matters. A system serving occasional appliance peaks has different requirements from one supporting sustained propulsion or a large overnight energy deficit. Use the expected load profile and available charging time to assess the generator size.

Match the Installation

Compare mounting positions, available space, cable routes, fuel connections, cooling-water arrangements and exhaust components against the offered assembly’s installation documents.

For a replacement, send the existing generator model and serial number, photographs of its identification plate and clear images of the surrounding installation. Include the reason for replacement so your installer can assess any underlying cooling, exhaust or electrical fault.

Understanding the 12.7 kW Continuous Rating

The power available to recharge batteries depends on what the boat is consuming while the generator runs.

As an illustrative example, if the generator delivers 12.7 kW and equipment on the same DC system consumes 3.5 kW, approximately 9.2 kW remains before cable and other system losses. Battery charge acceptance, temperature, state of charge and configured limits may reduce the charging power further.

This distinction helps when planning generator running time. A larger unit only shortens charging time when the battery bank and supporting equipment can accept the additional power.

Fischer Panda states that AGT-DC output must be limited to the published continuous performance when charging batteries. Use the 12.7 kW continuous reference when comparing packages, subject to the supplied configuration and operating conditions.

Controls, Charging Current and System Integration

The published reference uses fpControl. Identify the supplied panel, harness, remote-start arrangement and any communication equipment required by the vessel’s monitoring or energy-management system.

Fischer Panda specifies charging current as dependent on voltage. Obtain the permitted continuous current and charging settings for the offered configuration; dividing output by the battery bank’s nominal voltage alone does not establish a guaranteed charging-current rating.

Your installer should also establish suitable DC protection, isolation, cable sizing and the method of coordinating generator operation with other charging sources.

Installation Dimensions and Sound Insulation

The 760 × 515 × 613 mm dimensions describe the capsule, excluding fittings. Allow additional room for hoses, cables, mounting equipment, capsule removal and servicing.

Fischer Panda provides a reference drawing for article 0032928. Use the drawing applicable to the actual assembly when planning the installation.

The manufacturer’s 55 dB(A) at 7 metres is a published reference measurement. Noise aboard will also depend on generator location, mounting, structural vibration and exhaust arrangement. Discuss these installation factors when assessing comfort near cabins and living spaces.

Generator Package and Scope of Supply

Request an itemized quotation identifying the generator assembly, capsule, control panel, wiring harness, mountings and any installation accessories included.

Establish separately the battery bank, inverter, DC distribution equipment, fuel components, cooling-water equipment and exhaust parts required. Include installation labour and commissioning when comparing the total marine generator replacement cost.

For future service and parts enquiries, retain the manufacturer article number, generator serial number and supplied manuals. These identify the applicable equipment more precisely than the FPMA5008 listing reference alone.

Compare Related Fischer Panda DC Generators

For a lower-output option, compare the Fischer Panda AGT-DC 11000 PMS – FPMA5007. For a larger model, explore the Fischer Panda AGT-DC 22000 PMS – FPMA5010.

Compare continuous DC output, charging voltage, battery acceptance, installation requirements and package contents. Browse our Fischer Panda marine generators for other electrical configurations.

Fischer Panda AGT-DC 13000 Price, Delivery and Warranty

Request a Fischer Panda AGT-DC 13000 price for your required configuration and destination. The written quotation should identify the manufacturer article number, output voltage, equipment condition, scope of supply, current availability, dispatch estimate, freight charges and applicable taxes.

Obtain the warranty terms for the actual unit supplied, including the warrantor, coverage period, territory and any registration or commissioning requirements. Provide the operating location and any required emissions or vessel documentation before ordering.

Frequently Asked Questions

Is the AGT-DC 13000 an AC or DC generator?

It is a DC battery-charging generator. AC appliances require an appropriately specified inverter within the boat’s electrical system.

What is its continuous output?

Fischer Panda publishes 12.7 kW continuous for the AGT-DC 13000-48V PMS reference configuration.

Is FPMA5008 supplied as a 48V generator?

The manufacturer reference described here is 48V. Obtain written confirmation of the voltage supplied against FPMA5008 because the listing title does not specify it.

Can it charge lithium batteries?

Potentially, with an approved configuration. Battery charge limits, control interfaces and the response to a battery management system stop request require assessment.

Does it fit within a 760 × 515 × 613 mm space?

Those are approximate capsule dimensions excluding fittings. Additional space is needed for connections, mountings, servicing and capsule removal.

Does the price include batteries and an inverter?

Use the itemized quotation to establish what is included. Specify your battery and inverter requirements when requesting a complete system package.

Request Your Fischer Panda AGT-DC 13000 Quotation

For a Fischer Panda AGT-DC 13000 PMS marine generator for sale, contact Marine Inboard Specialists and quote FPMA5008.

Reviews

There are no reviews yet.


Be the first to review “Fischer Panda FPMA5008 – Generator AGT-DC 13000 PMS , KW/kVA 12.7/x, 2400-3000 RPM, 3 Cyl., 760 x 515 x 613”