Fischer Panda FPMA5006 – Generator AGT-DC 10000 PMS , KW/kVA 9.1/x, 2300-2900 RPM, 3 Cyl., 660 x 515 x 594
$21,188.00
- Description
- Reviews (0)
Description
Fischer Panda AGT-DC 10000 PMS Marine Generator for Sale – FPMA5006
The Fischer Panda AGT-DC 10000 PMS, listed under FPMA5006, is a diesel-powered DC battery-charging generator. Fischer Panda UK publishes 10.0 kW nominal / 9.1 kW continuous output for the AGT 10000 family, using a three-cylinder Kubota D722 diesel engine with variable-speed operation at 2,300–2,900 RPM.
Contact Marine Inboard Specialists for pricing, availability and a quotation matched to your battery system and installation. Confirm the offered generator’s DC voltage, controls, operating limits and package contents before ordering.
Request Price & Availability | Download Manufacturer Marine Brochure
DC Charging for Marine Battery and Inverter Systems
The AGT-DC 10000 can be evaluated for a compatible battery system supporting onboard electrical loads or an engineered hybrid propulsion installation. A suitable inverter supplies AC appliances from the battery bank.
Generator sizing should account for the power used by equipment while charging takes place. At a hypothetical operating point of 9.1 kW generator output, simultaneous DC-system demand of 3.0 kW would leave 6.1 kW before losses for battery charging.
Actual charging also depends on the bank’s permitted current, state of charge, temperature and charging profile. Include daily consumption in Ah or kWh, simultaneous loads and the available charging window with your enquiry.
Understanding the 9.1 kW Continuous Rating
Fischer Panda UK’s AGT 10000 overview distinguishes 10.0 kW nominal output from 9.1 kW continuous output. The manufacturer’s 2023 marine brochure also lists 9.1 kW continuous performance for the AGT-DC 10000-48V PMS reference.
For battery charging, use the applicable continuous rating and approved voltage/current limits. The brochure specifically states that AGT-DC performance must be limited to the continuous performance when batteries are used.
Specify this DC generator in kW, DC volts and charging amperes. The listing’s “9.1/x” field does not establish an AC kVA rating.
Fischer Panda FPMA5006 Technical Specifications
The figures below use the manufacturer’s 2023 AGT-DC 10000-48V brochure reference and UK AGT 10000 family specification. Confirm the actual supplied configuration using its identification plate and matched documentation.
| Specification | Published reference |
|---|---|
| Product family | Fischer Panda AGT-DC 10000 PMS |
| Listing reference | FPMA5006 |
| 2023 brochure designation | AGT-DC 10000-48V PMS |
| Continuous output | 9.1 kW |
| UK family nominal output | 10.0 kW |
| DC output voltage supplied | Confirm in quotation; brochure reference is 48 V |
| Charging current | Dependent on voltage; obtain applicable limits |
| Engine speed | Variable, 2,300–2,900 RPM |
| Diesel engine | Kubota D722 |
| Cylinders / displacement | 3 / 719 cm³ |
| Brochure control reference | VCS; confirm supplied package |
| Cooling circuits | 2 |
| Sound capsule | GFK 3D |
| Approximate capsule dimensions, L × W × H | 660 × 515 × 594 mm, excluding fittings |
| Published approximate weight, including capsule | 160 kg |
| Manufacturer article number and serial number | Confirm for the offered assembly |
| Starting system, panel and harness | Confirm against the supplied build |
Sources: Fischer Panda 2023 marine brochure and UK AGT 10000 specification. The manufacturer’s 2020 brochure also documents the D722, VCS and capsule specifications above.
Confirming the Voltage and Generator Build
Fischer Panda’s UK overview lists 12 V, 24 V and 48 V options, while the cited brochure identifies an AGT-DC 10000-48V version. The FPMA5006 listing does not identify its output voltage, so include your required battery-system voltage in the enquiry.
The UK page also links a separate 24 V specification sheet stating 8.0 kW continuous output and different capsule details. This demonstrates why specifications from different AGT 10000 documents should be matched to the actual assembly rather than combined.
Request one coherent specification covering the quoted unit’s voltage, continuous output, charging limits, controls, dimensions and starting arrangement.
View Separate Manufacturer 24 V Specification Reference | View Manufacturer’s 48 V Reference Drawing
Kubota Diesel, Marine Cooling and VCS Controls
The published reference uses a 719 cm³ Kubota D722 three-cylinder diesel. Fischer Panda UK describes two cooling circuits using a heat exchanger and sealed freshwater circuit.
The 2023 brochure identifies VCS controls for the AGT-DC 10000. Confirm the fitted regulation equipment, panel, harness and monitoring interfaces when planning a replacement or integration with an existing energy system.
Have the installer assess cooling-water supply, exhaust routing, mounting support and service access against the manual for the supplied generator. For a replacement following overheating or water ingress, include an assessment of the original failure and associated vessel systems.
Is This the Right Marine DC Generator for Your Boat?
Match the Battery System
Provide the battery manufacturer, model, chemistry, nominal voltage and capacity. Include the permitted charging voltage and current.
For lithium batteries, obtain confirmation that the generator’s charging profile, current limits and shutdown sequence are compatible with the BMS. Battery voltage alone does not establish compatibility.
Match the Controls and Electrical Installation
Provide the inverter, battery monitor, other charging sources and any automatic-start requirements. For electric propulsion, include the motor, controller and normal cruising demand.
Have a qualified marine electrician assess DC protection, isolation, cable routing and voltage drop for the proposed charging current. Establish which existing controls and cables can be retained after checking the offered assembly.
Match the Installation Space
Measure the compartment, access opening and mounting footprint. Capsule dimensions exclude fittings; allow space for connections, mounting hardware, capsule removal and routine servicing.
For a replacement, send photographs of the existing generator plate, controls, mounting base and cooling, fuel and exhaust connections.
AGT-DC 10000 and AGT-DC 11000 References
The manufacturer’s 2023 brochure lists these as separate configurations: AGT-DC 10000 with 9.1 kW, Kubota D722 and VCS, and AGT-DC 11000 with 10.9 kW, Kubota D902 and fpControl.
Their model names do not establish interchangeable generators, controls or installation equipment. Compare the exact assembly, battery-system requirements and complete package before selecting a replacement.
Sound Levels and Fuel Consumption
The 2023 brochure reports 53 dB(A) at 7 metres for its AGT-DC 10000-48V reference. Installed sound depends on the compartment, mounts, exhaust arrangement and operating conditions.
Request fuel-consumption information for the quoted build at your intended charging load. Compare running costs using the energy restored to the battery bank, simultaneous onboard demand and charging losses.
Scope of Supply
An itemised quotation should identify the generator assembly, sound capsule, charging regulation equipment, control panel, harness, mounting hardware and supplied documentation.
Confirm separately whether the starter battery, house batteries, inverter, battery monitor, BMS interfaces, cooling and exhaust installation parts, service kit, installation labour and commissioning are included.
This helps establish the complete marine DC generator replacement cost.
Compare Related Fischer Panda DC Generators
For another DC charging option, review the Fischer Panda AGT-DC 8000-48V PMS – FPMA5005.
For a higher-output reference, explore the Fischer Panda AGT-DC 11000 PMS – FPMA5007. Confirm its supplied voltage, controls and installation requirements.
Browse the wider Fischer Panda Marine Generator range when comparing other configurations.
AGT-DC 10000 Price, Warranty and Delivery
Request a Fischer Panda AGT-DC 10000 price for the voltage, charging configuration and delivery destination you need. The quotation should state condition, manufacturer reference, package contents, availability, dispatch estimate, freight charges and applicable taxes.
Obtain written warranty terms identifying the warrantor, coverage period, territory and registration or commissioning requirements.
Provide the operating country, vessel flag and any required emissions or classification documents. Confirm the approvals applicable to the actual generator supplied before purchase.
Frequently Asked Questions
Is 9.1 kW a continuous rating?
Yes. The cited UK family specification and 2023 brochure list 9.1 kW continuous output. Have the quotation confirm that the offered assembly matches that reference.
Is FPMA5006 a 48 V generator?
The cited brochure documents a 48 V version, but the FPMA5006 listing does not specify voltage. Confirm the supplied DC voltage and charging configuration before ordering.
Can it supply 230 V AC appliances?
A compatible battery system and appropriately specified inverter can supply AC appliances. Include the inverter rating and connected loads with your enquiry.
Can I reuse my existing VCS panel?
Compatibility requires assessment of the offered generator, regulation equipment, panel and harness. Provide the existing identification details and photographs before planning reuse.
Is it suitable for lithium batteries?
Compatibility must be confirmed for the battery model, charging profile, permitted current and BMS shutdown requirements. Supply the battery and BMS documentation for assessment.
Are batteries and an inverter included?
Confirm these in the itemised quotation. They are separate system components and should be expressly listed if included.
Request Your Fischer Panda FPMA5006 Quotation
For a Fischer Panda AGT-DC 10000 PMS marine generator for sale, contact Marine Inboard Specialists with your vessel type, required DC voltage, battery specifications, inverter or propulsion-system details, daily energy demand and installation space.
Include how soon you want to purchase, your required delivery date, and your billing and delivery addresses. For a replacement, attach photographs of the existing generator identification plate, controls and installation.






Reviews