Fischer Panda 30 PMS Marine Diesel Generator for Sale – FPMA3008

The Fischer Panda 30 PMS, listed under FPMA3008, is a marine diesel generator with a nominal output of 25.5 kW / 30 kVA, a four-cylinder turbo diesel engine and an operating speed of 3,000 RPM. It is an option for vessel owners assessing onboard AC power or replacing an existing marine genset.

Contact Marine Inboard Specialists for price, availability and a quotation matched to your electrical supply and installation. Confirm the voltage, phase, operating requirements and package contents before ordering.

Request Price & Availability | View Fischer Panda Marine Brochure

Kubota Diesel Power and Marine Cooling

Fischer Panda’s historical Panda 30 PMS specification identifies a Kubota V1505T engine, 1,498 cm³ displacement, two cooling circuits and a GFK capsule with 3D sound insulation.

The generator can be evaluated for loads such as air conditioning, refrigeration, battery chargers, galley equipment and pumps. Correct sizing depends on the equipment operating together and the starting demand of the largest motors.

Cooling, exhaust routing, mounting and service access are part of the installation assessment. For a replacement following overheating or water ingress, have the installer establish the cause of the failure and assess the associated boat-side systems before fitting another generator.

Fischer Panda FPMA3008 Technical Specifications

The reference figures below are documented in Fischer Panda’s Marine Generators 2015/2016 brochure for the Panda 30 PMS. Match the offered generator to its identification plate, applicable manual and supply documents.

Specification Panda 30 PMS reference
Manufacturer Fischer Panda
Listing reference FPMA3008
Nominal electrical output 25.5 kW / 30.0 kVA
Engine speed 3,000 RPM
Engine model Kubota V1505T diesel
Listed cylinder configuration Four-cylinder turbo diesel, “4TD”
Engine displacement 1,498 cm³
Published 50 Hz versions 230 V single-phase; 400 V three-phase
Cooling circuits 2
Sound capsule GFK with 3D insulation
Approximate capsule dimensions, L × W × H 1,010 × 515 × 674 mm, excluding fittings
Approximate weight, including capsule 403 kg
Supplied voltage, controls and accessories Confirm in the quotation

The currently linked Panda 30x datasheet corroborates the output, speed, engine, displacement, capsule dimensions and weight shown above.

Installation dimensions: The product listing gives 1,010 × 515 × 670 mm. The manufacturer’s brochure and currently linked Panda 30x datasheet specify a 674 mm capsule height. Obtain the drawing for the actual unit supplied and allow additional space for connections, mounts and maintenance.

Understanding 25.5 kW / 30 kVA

The Panda 30 PMS is listed at 25.5 kW of real electrical power and 30 kVA of apparent power. At a power factor of 0.85, 30 kVA × 0.85 = 25.5 kW. The “30” model designation should therefore not be read as a 30 kW rating.

Fischer Panda’s historical brochure qualifies the kVA figures for this generator class by reference to optional starting compensation or a starting-current booster. Confirm the starting equipment fitted to the offered unit.

As a planning example, a hypothetical 22 kW running load plus a 5 kW additional load totals 27 kW, exceeding the nominal output before accounting for motor starting demand. A load schedule helps identify whether equipment needs to start sequentially or whether a different generator is required.

For long daily operating periods, request the manufacturer’s sustained-load guidance and operating limits for the supplied build.

Checking Panda 30 PMS and Panda 30x References

Fischer Panda’s current range uses the designation Panda 30x PMS. Its published 230 V, single-phase, 50 Hz specification also lists 25.5 kW / 30 kVA at 3,000 RPM, with a Kubota V1505T engine.

Current documentation identifies a 12 V starting system, xControl / fpControl and voltage regulation of ±3 V. Establish which controls and starting arrangement are fitted to the offered FPMA3008 unit.

Download Current Panda 30x PMS Datasheet | View Manufacturer’s Linked Installation Drawing

Matching model-family ratings do not establish identical equipment. Use the manufacturer article number and serial number to identify the applicable documentation and replacement parts.

Is This the Right Replacement Marine Generator?

Match the Electrical Supply

Provide the vessel’s required voltage, frequency and phase arrangement, together with its equipment load schedule. Include motor starting currents where available.

For a three-phase installation, have a qualified marine electrician assess phase loading, distribution equipment and shore-power transfer arrangements as well as total demand.

Match the Installation

Send compartment measurements and photographs showing the mounting base, access opening, cooling connections, fuel supply and exhaust route. Check access for capsule removal and routine servicing.

If replacing a Panda 24 PMS, note that the historical brochure gives the same capsule dimensions for both models but different weights: 355 kg for Panda 24 PMS and 403 kg for Panda 30 PMS. Similar dimensions alone do not establish a direct replacement or adequate mounting capacity.

Match the Controls

Identify the existing control panel, harness, starting battery supply and any remote-start or vessel-monitoring requirements. Confirm which components can be retained and which require replacement.

Include the current generator model and serial number, operating hours and reason for replacement with your enquiry.

Sound Levels and Fuel Consumption

Fischer Panda’s brochure reports 55 dB(A) at 7 metres for the Panda 30 PMS, also shown in the current 30x datasheet. Installed sound levels depend on the compartment, mounting and exhaust arrangement.

Request fuel-consumption information for the offered generator at your expected operating load. Use that data when planning running costs and onboard fuel requirements.

Scope of Supply

An itemised quotation should identify the generator assembly, sound capsule, control panel, wiring harness, AC control or connection equipment where applicable, mounting hardware and supplied documentation.

Confirm separately whether the starting battery, cooling and exhaust installation parts, service kit, delivery, installation labour and commissioning are included. This provides a clearer comparison of the complete marine generator replacement cost.

Compare Related Fischer Panda Marine Generators

For lower-output alternatives, explore the Fischer Panda 24 PMS Marine Generator – FPMA3007 and Fischer Panda 18 PMS Marine Generator – FPMA3006.

Browse the wider Fischer Panda Marine Generator range when comparing other configurations. Assess output, voltage, phase, starting capacity, installation requirements and supplied equipment together.

Fischer Panda 30 PMS Price, Warranty and Delivery

Request a Fischer Panda 30 PMS price for the required configuration and delivery destination. The quotation should state the generator’s condition, manufacturer reference, package contents, availability, dispatch estimate, freight and applicable taxes.

Obtain written warranty terms identifying the warrantor, coverage period, territory and any registration or commissioning requirements. Include these conditions in the installation schedule.

For regulated or classed vessels, state the operating country, flag and required emissions or classification documents. Confirm compliance using the documentation for the actual generator supplied.

Frequently Asked Questions

Is the Panda 30 PMS a 30 kW generator?

Its listed nominal output is 25.5 kW / 30 kVA. Use both ratings, together with motor starting requirements, when assessing your vessel’s loads.

What does “4TD” mean?

The listing uses “4TD” for a four-cylinder turbo diesel configuration. Fischer Panda’s historical specification identifies the engine as a Kubota V1505T.

Is FPMA3008 supplied as 230 V or 400 V?

Confirm the supplied version in the quotation. The manufacturer’s historical brochure documents 230 V single-phase and 400 V three-phase 50 Hz configurations.

Can it replace my existing Panda 24 PMS?

It can be assessed, but dimensions alone are insufficient. Check mounting capacity, electrical configuration, cooling, exhaust, controls and starting demand before selecting the replacement.

Can it operate for extended periods each day?

Confirm the applicable sustained-load limits, maintenance schedule and installation requirements for the offered build against your expected hours and load profile.

Does the price include the control panel and installation kit?

The quotation should itemise these components. Confirm panel type, harness, mounting equipment, installation accessories and commissioning separately.

Request Your Fischer Panda 30 PMS Quotation

For a Fischer Panda FPMA3008 Generator 30 PMS for sale, contact Marine Inboard Specialists with your vessel type, required voltage and phase, load schedule, intended running hours and available installation space.

Include how soon you want to purchase, your required delivery date, and your billing and delivery addresses. For a replacement, attach photographs of the current identification plate, control panel and installation.

Reviews

There are no reviews yet.


Be the first to review “Fischer Panda FPMA3008 – Generator 30 PMS, KW/kVA 25.5/30, 3000 RPM, Cyl. 4TD, 1010 x 515 x 670”