Fischer Panda FPVG0206 – FP Generator 12000 PVK-U, KW/kVA 10.2 / 12.0, 3000 RPM, 3 Cyl., 960 x 5130 x 625
$21,918.00
- Description
- Reviews (0)
Description
Fischer Panda 12000 PVK-U Generator for Sale – FPVG0206
The Fischer Panda 12000 PVK-U, listed under reference FPVG0206, is a three-cylinder diesel vehicle generator with a published nominal output of 10.2 kW / 12.0 kVA at a fixed 3,000 RPM. Fischer Panda’s current corresponding reference is the 12000x PVK-U.
Contact Marine Inboard Specialists for a quotation covering the generator, controls, remote radiator and installation equipment required for your project.
The documented reference capsule measures 960 × 530 × 625 mm, excluding fittings. Confirm the complete installation envelope, electrical configuration and manufacturer article number before ordering.
Request Price & Availability | Download Manufacturer Datasheet
Fixed-Speed Power with a Kubota Diesel Engine
The 12000x PVK-U belongs to Fischer Panda’s xSeries Compact Power range. The identified reference uses a Kubota D722 three-cylinder diesel engine, with 719 cm³ displacement, a 12 V starter system and xControl / fpControl equipment.
For a new vehicle installation or generator replacement, start with the electrical equipment that must operate together. Battery chargers, heaters, refrigeration, air conditioning, pumps and workshop equipment need assessment against their running loads and starting demand.
The 12000 model name should be read alongside the published ratings. Its nominal real-power figure is 10.2 kW.
External Chassis Installation with Remote Cooling
PVK-U identifies an external vehicle generator arrangement requiring a separate radiator. Fischer Panda describes a metal capsule with a removable cover, chassis mounting provisions and a water-cooled exhaust silencer inside the enclosure.
The separate radiator allows cooling equipment to occupy a different location from the generator. Radiator airflow, coolant routing, fan supply and service access therefore form part of the complete installation assessment.
Fischer Panda distinguishes this arrangement from PVK-UK, which incorporates an integrated radiator, and PVMV-N, which is intended for internal vehicle installation with remote cooling. Specify a vessel application explicitly if the project requires a marine generator configuration.
Confirm Voltage and Phase Before Ordering
The manufacturer’s 230 V reference, article 0033132, supplies 50 Hz, single-phase AC power. Fischer Panda also lists a separate 12000x-400V PVK-U, supplying 400 V, 50 Hz, three-phase power, with the same published nominal 10.2 kW / 12.0 kVA figures.
The supplied FPVG0206 listing does not identify voltage or phase. Have the quotation state both, together with the actual manufacturer article number.
For a three-phase installation, have your electrician assess load distribution, allowable single-phase loading and motor compatibility. The total generator rating alone does not establish the permitted load on an individual phase.
Technical Specifications
The table below uses the manufacturer’s 230 V 12000x PVK-U reference, article 0033132. Match these figures to the assembly offered under FPVG0206.
| Specification | Published reference |
|---|---|
| Product listing reference | FPVG0206 |
| Listing model | Fischer Panda 12000 PVK-U |
| Current manufacturer reference | Panda 12000x PVK-U |
| Reference manufacturer article number | 0033132 |
| Generator family | xSeries – Compact Power |
| Application | External vehicle chassis installation |
| Nominal electrical output | 10.2 kW / 12.0 kVA |
| Reference AC voltage / frequency | 230 V / 50 Hz |
| Reference phase configuration | Single-phase |
| Engine speed | Fixed 3,000 RPM |
| Fuel type | Diesel |
| Engine manufacturer / model | Kubota D722 |
| Cylinders / displacement | 3 / 719 cm³ |
| Starter system | 12 V |
| Reference control system | xControl / fpControl |
| Capsule designation | MPL 4DS |
| Capsule dimensions, L × W × H | 960 × 530 × 625 mm, excluding fittings |
| Published generator weight with capsule | Approximately 317 kg |
| Published sound level | 53 dB(A) at 7 metres |
| Cooling arrangement | Separate external radiator required |
| Continuous operating rating | Confirm for the supplied assembly and operating conditions |
Sources: Fischer Panda 12000x PVK-U manufacturer datasheet and 2026 vehicle generator brochure. Separately mounted equipment, fittings and installation clearances require additional allowance.
The published 317 kg figure includes the generator capsule. Establish total installed weight separately, including radiator, coolant, mounting structure and accessories. Assess the published sound figure alongside radiator-fan noise and the vehicle’s mounting arrangement.
Understanding 10.2 kW and 12.0 kVA
Kilowatts describe real electrical power; kilovolt-amperes describe apparent power. The manufacturer pairs 10.2 kW and 12.0 kVA using a 0.85 factor.
Fischer Panda’s vehicle brochure explains that, for this asynchronous generator range, the kVA calculation at 0.85 relates to short starting performance for inductive consumers. Request the applicable continuous-output rating and starting-performance information for the offered assembly.
For example, a charger drawing 3.0 kW from the AC supply, a 2.0 kW heater and 2.5 kW of other equipment total 7.5 kW before cooling accessories or a motor start. This illustrative running-load total helps prepare an enquiry; starting current, power factor and permissible sustained load still need assessment.
Is This the Right Replacement Generator?
Use three checks when planning the installation: match the electrical system, match the mounting space and match the cooling package.
Match the Electrical System
Provide the existing generator’s model, serial number, rated output, voltage, frequency and phase. Include a load schedule, daily running hours and starting-current information for the largest motors where available.
Have your installer assess electrical protection, shore-power changeover, charger integration and control compatibility. Identify the control-panel version and cable lengths required for the proposed installation.
Match the Mounting Space
Measure available chassis space, ground clearance and service access. Allow room for hose connections, wiring, cover removal and routine maintenance.
Provide photographs of the existing mounts, structural supports and connection positions. Request the installation drawing applicable to the offered assembly before finalising mounting points or vehicle modifications.
Match the Cooling Package
Identify the proposed radiator location, available airflow, expected ambient temperature and coolant-hose route. Include access for cleaning and maintenance.
The manufacturer lists radiator options with 24 V DC or 230 V AC fan supplies. Confirm the selected fan supply separately from the generator’s 12 V starting system.
If the previous generator overheated, assess radiator condition, airflow and cooling-circuit performance before commissioning its replacement.
Generator Package and Scope of Supply
Request an itemised quotation identifying the generator assembly, control panel, electrical control equipment, wiring, radiator, fan controls, fuel connections, mounting components and exhaust installation parts included.
State which existing components you intend to retain. Compatibility should be checked by model and part number, particularly for older controls and cooling equipment.
Identify installation labour, vehicle modifications, commissioning, manuals and required documentation separately. This establishes the complete vehicle generator replacement cost and helps you compare quotations accurately.
Compare Related Fischer Panda Generators
For lower electrical demand with external mounting and remote cooling, compare the Fischer Panda FPVG0205 10000 PVK-U. Review its applicable output rating and installation requirements against your load schedule.
For an external configuration incorporating its radiator, explore the Fischer Panda FPVG0306 12000 PVK-UK. The integrated cooling arrangement changes the space and mounting assessment.
Fischer Panda 12000 PVK-U Price, Delivery and Warranty
Request a Fischer Panda 12000 PVK-U price for the required electrical configuration, package contents and delivery destination. The written quotation should identify the actual manufacturer reference, equipment condition, current availability, dispatch estimate, freight charges and applicable taxes.
Obtain warranty terms for the actual generator supplied, including the warrantor, coverage period, territory and registration or commissioning requirements.
For international orders, provide the destination country and any required emissions or conformity documentation so the quotation addresses the correct configuration and supply documents.
Frequently Asked Questions
Is the Fischer Panda 12000 PVK-U a 12 kW generator?
Its published nominal output is 10.2 kW / 12.0 kVA. The model name and kVA figure should not be treated as its real-power rating.
Is it a fixed-speed generator?
The documented 12000x PVK-U operates at 3,000 RPM in its 50 Hz configuration.
Is FPVG0206 single-phase or three-phase?
The supplied listing does not identify phase. The table uses a 230 V single-phase reference; Fischer Panda separately lists a 400 V three-phase version. Confirm the actual configuration in the quotation.
Does the PVK-U have an integrated radiator?
It requires a separate radiator. The itemised quotation establishes whether the radiator, fan controls and cooling accessories are included.
What are the reference dimensions and weight?
The identified reference capsule measures 960 × 530 × 625 mm, excluding fittings, and weighs approximately 317 kg with capsule. Allow additional space and weight for the complete installation.
Can it replace my existing vehicle generator?
Potentially. Provide the existing generator identification, electrical requirements, mounting measurements and cooling-system details so compatibility can be assessed before purchase.
Request Your Fischer Panda FPVG0206 Quotation
For a Fischer Panda 12000 PVK-U generator for sale, contact Marine Inboard Specialists with reference FPVG0206.
Include your vehicle type, electrical load schedule, required voltage and phase, daily operating hours, available mounting space and proposed radiator location. State how soon you want to purchase, your required delivery date, and your billing and delivery addresses.
For replacement projects, attach photographs of the existing generator plate, control panel, mounts and radiator installation.







Reviews