Fischer Panda FPVG0205 – FP Generator 10000 PVK-U, KW/kVA 8.0 / 9.0, 3000 RPM, 2 Cyl.
$23,918.00
- Description
- Reviews (0)
Description
Fischer Panda 10000 PVK-U Generator for Sale – FPVG0205
The Fischer Panda 10000 PVK-U, listed under reference FPVG0205, is a two-cylinder diesel vehicle generator operating at a fixed 3,000 RPM. The current manufacturer reference, Panda 10000x PVK-U, supplies 230 V, 50 Hz, single-phase AC power with a published nominal output of 8.0 kW / 9.4 kVA.
Contact Marine Inboard Specialists for a quotation covering the generator, controls, cooling equipment and installation accessories required for your project.
Specification note: The supplied FPVG0205 listing states 8.0 kW / 9.0 kVA. Fischer Panda’s current 10000x PVK-U documentation lists 8.0 kW / 9.4 kVA. Confirm the offered unit’s manufacturer article number and applicable rating before ordering.
Request Price & Availability | View Manufacturer Specifications
Fixed-Speed Power for Vehicle Equipment
The 10000x PVK-U belongs to Fischer Panda’s fixed-speed vehicle generator range. Its two-cylinder Kubota Z602 diesel engine operates at 3,000 RPM in the documented 50 Hz configuration. Fischer Panda UK identifies applications including battery charging, vehicle appliances and monitoring or communication equipment.
For selection, start with the equipment that must operate together and the intended daily running hours. Compressor and pump starting demand, radiator-fan consumption and charger input should be included alongside ordinary running loads.
The 10000 model name does not establish a 10 kW output. Use the published electrical ratings and the supplied assembly’s operating documentation when comparing quotations.
External Installation with a Separate Radiator
PVK-U identifies a vehicle generator arrangement for external chassis mounting with a separate radiator. Fischer Panda describes a metal enclosure with a removable cover and a water-cooled exhaust silencer inside the sound-insulation capsule.
The remote radiator requires its own mounting position, airflow and coolant connections. Include these components when assessing installation space and the complete package cost.
Fischer Panda distinguishes PVK-U from PVK-UK, which incorporates an integrated radiator, and PVMV-N, which is intended for internal vehicle installation with remote cooling. For a vessel project, specify the marine application before selecting a generator configuration.
Technical Specifications
The following reference figures describe Fischer Panda’s current 10000x PVK-U, article 0031894. They should be matched to the actual assembly offered under FPVG0205.
| Specification | Published reference |
|---|---|
| Product listing reference | FPVG0205 |
| Listing model | Fischer Panda 10000 PVK-U |
| Current manufacturer reference | Panda 10000x PVK-U |
| Reference manufacturer article number | 0031894 |
| Generator family | xSeries – Compact Power |
| Installation arrangement | External vehicle chassis mounting |
| Nominal electrical output | 8.0 kW / 9.4 kVA |
| AC voltage / frequency | 230 V / 50 Hz |
| Phase configuration | Single-phase |
| Engine speed | Fixed 3,000 RPM |
| Fuel type | Diesel |
| Engine manufacturer / model | Kubota Z602 |
| Cylinders / displacement | 2 / 599 cm³ |
| Starter system | 12 V |
| Current reference control system | xControl / fpControl |
| Capsule designation | MPL 4DS |
| Capsule dimensions, L × W × H | 910 × 522 × 620 mm, excluding fittings |
| Published weight with capsule | Approximately 290 kg |
| Published sound level | 52 dB(A) at 7 metres |
| Cooling | Separate external radiator |
| Continuous operating rating | Confirm for the supplied assembly |
Sources: Fischer Panda manufacturer specifications and UK reference specification sheet. Control equipment and package contents must be established in the quotation.
The capsule dimensions exclude fittings and installation clearances. Allow additional room for connections, mounting hardware, cover removal and servicing. Confirm the total installed weight, including radiator, coolant and accessories.
Understanding Output and Starting Demand
8.0 kW describes nominal real power; 9.4 kVA describes the published apparent-power figure. Both ratings need to be assessed against the connected equipment.
Fischer Panda’s vehicle brochure explains that, for this asynchronous generator range, the kVA calculation using a 0.85 factor relates to short starting performance for inductive consumers. Request the applicable continuous-output rating and starting-performance information for the offered generator.
For example, a charger drawing 2.8 kW from the AC supply, a 2.0 kW heater and 1.2 kW of other equipment total 6.0 kW before radiator fans or a motor start. This illustrative running-load calculation helps prepare an enquiry; the installer still needs to assess starting current and permissible sustained load.
Is This the Right Replacement Generator?
Use three checks when planning a replacement: match the electrical system, match the mounting space and match the cooling arrangement.
Match the Electrical System
Provide the existing generator’s model, serial number, output, voltage, frequency and phase configuration. Include the connected equipment schedule, daily running hours and the largest motor-starting load.
Have your installer assess electrical protection, shore-power changeover, inverter/charger integration and control compatibility. Similar output figures alone do not establish that the replacement will connect to the existing installation.
Match the Mounting Space
Measure chassis space, ground clearance and service access. Include photographs of structural supports, current mounts and connection positions.
Fischer Panda publishes a 10000x PVK-U reference drawing for article 0031894. Obtain the drawing revision applicable to the offered assembly before finalising mounting arrangements.
Match the Cooling Arrangement
Identify the proposed radiator position, available airflow, expected ambient temperature and coolant-hose route. Include access for cleaning and maintenance.
The manufacturer lists radiator options with 24 V DC or 230 V AC fan supplies. Establish the selected fan supply separately from the generator’s 12 V starting system.
If the existing generator failed after overheating, assess radiator condition, airflow and cooling performance before commissioning the replacement.
Generator Package and Scope of Supply
Request an itemised quotation identifying the generator assembly, control panel, electrical control equipment, wiring harnesses, radiator, fan controls, fuel connections, mounting components and exhaust installation parts included.
State which existing components you intend to retain. Compatibility should be checked by model and part number, particularly for older control panels and cooling equipment.
Identify installation labour, vehicle modifications, commissioning and documentation separately. This establishes the complete vehicle generator replacement cost and helps you compare offers accurately.
Compare Fischer Panda Installation Options
Browse the Fischer Panda generator range to compare other capacities and installation arrangements.
If your project is a boat installation, explore the Fischer Panda FPMA1005 10000i PMS marine generator. It has a different generation and cooling arrangement, so its installation requirements need a separate assessment.
Fischer Panda 10000 PVK-U Price, Delivery and Warranty
Request a Fischer Panda 10000 PVK-U price for the required equipment package and destination. The quotation should identify the manufacturer article number, equipment condition, supplied accessories, current availability, dispatch estimate, freight charges and applicable taxes.
Obtain written warranty terms for the actual generator supplied, including the warrantor, coverage period, territory and registration or commissioning requirements.
For international orders, provide the destination country and any required emissions or conformity documentation. Confirm that the documents supplied correspond to the actual engine and generator configuration.
Frequently Asked Questions
Is the Fischer Panda 10000 PVK-U a 10 kW generator?
The current 10000x PVK-U reference is rated at 8.0 kW / 9.4 kVA nominal output. The model name should not be used as its kW rating.
Why does the FPVG0205 listing say 9.0 kVA?
The supplied listing and current manufacturer reference differ. Have the supplier confirm the offered article number, rating plate and applicable specification in the quotation.
Is it fixed-speed or variable-speed?
The documented 10000x PVK-U operates at a fixed 3,000 RPM. Fischer Panda’s iSeries models use a different variable-speed arrangement.
Does the PVK-U include an integrated radiator?
It requires a separate radiator. The itemised quotation establishes whether the radiator, fan controls and cooling accessories are included.
Can I reuse my existing controls and mounts?
Potentially. Provide their identification details, measurements and photographs so compatibility can be assessed before reuse.
What are the reference dimensions and weight?
The published capsule measures 910 × 522 × 620 mm, excluding fittings, with a weight of approximately 290 kg including the capsule. Allow for separately installed equipment and service clearances.
Request Your Fischer Panda FPVG0205 Quotation
For a Fischer Panda 10000 PVK-U generator for sale, contact Marine Inboard Specialists with reference FPVG0205.
Include the vehicle type, electrical load schedule, required voltage and frequency, daily operating hours, mounting-space measurements and proposed radiator location. State how soon you want to purchase, your required delivery date, and your billing and delivery addresses.
For replacements, attach photographs of the existing generator plate, control panel, mounts and radiator installation.







Reviews