Fischer Panda FPVG0305 – FP Generator 10000 PVK-UK, KW/kVA 8.0 / 9.0, 3000 RPM, 2 Cyl.
$21,918.00
- Description
- Reviews (0)
Description
Fischer Panda 10000 PVK-UK Generator for Sale – FPVG0305
The Fischer Panda 10000 PVK-UK, listed under reference FPVG0305, is a two-cylinder diesel vehicle generator operating at a fixed 3,000 RPM. Its integrated radiator arrangement suits projects requiring an externally mounted generator with cooling equipment incorporated into the assembly.
Contact Marine Inboard Specialists for a quotation covering the generator configuration, controls and installation accessories required for your vehicle.
Specification note: Your listing states 8.0 kW / 9.0 kVA, which also appears in Fischer Panda UK’s downloadable reference sheet. Fischer Panda’s current 10000x PVK-UK product pages publish 8.0 kW / 9.4 kVA. Confirm the manufacturer article number, rating plate and applicable specification for the offered unit before ordering.
Request Price & Availability | View Manufacturer Specifications
Fixed-Speed Power for Vehicle Equipment
The current Panda 10000x PVK-UK belongs to Fischer Panda’s xSeries vehicle generator range. The documented single-phase configuration supplies 230 V, 50 Hz AC power. Fischer Panda UK identifies applications including battery charging, onboard appliances and monitoring or communication equipment.
For selection, identify which equipment must operate together, the largest starting load and expected daily operating hours. A vehicle running battery chargers and refrigeration has a different demand profile from one supplying heating or workshop equipment.
The 10000 model name does not establish a 10 kW output. Compare the electrical rating, operating conditions and complete equipment package when assessing alternatives.
External Installation with an Integrated Radiator
PVK-UK identifies Fischer Panda’s external vehicle installation arrangement with an integrated radiator and cooling system. The manufacturer describes a metal capsule with a heavy-duty cover, mounting bolts and a wide access hatch. This arrangement brings the cooling equipment into the generator package and removes the need to position a separate remote radiator.
The installation still needs suitable airflow, structural support, connection space and maintenance access. Include radiator intake and discharge paths when evaluating the proposed chassis position.
Fischer Panda distinguishes this configuration from PVK-U, which requires a separate radiator, and PVMV-N, intended for internal vehicle installation with remote cooling. For a boat project, state the marine application so an appropriate generator arrangement can be selected.
Fischer Panda FPVG0305 Technical Specifications
The following figures describe the manufacturer’s published 10000x PVK-UK reference configuration. The offered assembly must be matched to its own identification and supply documents.
| Specification | Published reference |
|---|---|
| Product listing reference | FPVG0305 |
| Manufacturer reference model | Panda 10000x PVK-UK |
| Manufacturer article number | Confirm with quotation |
| Generator family | xSeries – Compact Power |
| Installation | External vehicle mounting, integrated radiator |
| Nominal electrical output | 8.0 kW / 9.4 kVA |
| Reference AC supply | 230 V / 50 Hz / single-phase |
| Engine operating speed | Fixed 3,000 RPM |
| Diesel engine | Kubota Z602 |
| Cylinders / displacement | 2 / 599 cm³ |
| Electric starting system | 12 V |
| Published control system | xControl / fpControl |
| Sound-insulation capsule | MPL 4DS |
| Capsule size, L × W × H | 1,516 × 522 × 620 mm, excluding fittings |
| Weight including capsule | Approximately 340 kg |
| Published acoustic reference | 52 dB(A) at 7 metres |
| Cooling arrangement | Integrated radiator |
| Permitted sustained load | Confirm for the supplied assembly |
Sources: manufacturer product data and Fischer Panda vehicle generator brochure.
Fischer Panda also documents a separate 400 V, three-phase 10000x PVK-UK version. Specify the required voltage and phase configuration; the FPVG0305 listing alone does not establish which winding will be supplied.
Understanding kW, kVA and Starting Loads
kW measures real electrical power, while kVA measures apparent power. Both matter when selecting a generator for equipment with motors, compressors or electronic power supplies.
Fischer Panda’s vehicle brochure explains that the 0.85 factor used for this asynchronous range’s kVA figure relates to short starting performance for inductive consumers. It should not be interpreted as additional continuous real-power capacity. Request the applicable sustained-output and starting-performance information for the supplied generator.
As a planning example, a charger drawing 2.5 kW from the AC supply, a 2.0 kW heater and 1.0 kW of other equipment total 5.5 kW before auxiliary loads and motor starting. This illustrative calculation helps prepare an enquiry; it does not establish that every combination will start or run satisfactorily.
Three Checks Before Replacing Your Generator
Match the Electrical Installation
Provide the existing generator’s model, serial number, voltage, frequency, phase configuration and rated output. Include a load schedule showing equipment that runs simultaneously and any known starting-current requirements.
Have your installer assess distribution protection, shore-power changeover, inverter/charger integration and control compatibility. Identify any equipment you intend to retain by model or part number.
Match the Chassis Space and Service Access
Measure the available mounting envelope, ground clearance and access for maintenance. Provide photographs showing structural supports, nearby equipment and current connection positions.
The published dimensions cover the capsule; fittings, mounting hardware, hoses and cables require additional space. Obtain the drawing revision applicable to the offered assembly before finalising brackets or chassis modifications.
Match the Cooling and Exhaust Arrangement
Show the proposed radiator airflow route, nearby heat sources, expected operating environment and exhaust outlet position. Include access for radiator cleaning and routine servicing.
An integrated radiator simplifies component placement, but its suitability still depends on the installation. If replacing a generator after overheating, investigate airflow and cooling condition before commissioning the replacement.
Generator Package and Scope of Supply
Request an itemised quotation identifying the generator assembly, integrated cooling equipment, control panel, electrical control or booster equipment, wiring looms, fuel-system components, mounting parts and exhaust installation accessories included.
Fischer Panda UK’s reference sheet describes a remote control/booster box, fuel pump, connecting looms and remote panel. Use that document as a reference when discussing package contents; establish the actual supplied equipment in the quotation.
Identify installation labour, vehicle modifications, commissioning, documentation and optional service spares separately. This makes the complete project cost easier to compare and establishes responsibility for each part of the installation.
Compare Other Fischer Panda Vehicle Generators
Consider the Fischer Panda FPVG0205 10000 PVK-U if your layout requires a separate radiator.
For greater output within the integrated-radiator format, compare the Fischer Panda FPVG0306 12000 PVK-UK.
Compare electrical configuration, starting capability, installation space and package contents alongside the model name.
Price, Availability, Delivery and Warranty
Request a Fischer Panda 10000 PVK-UK price for your required configuration and destination. The quotation should identify equipment condition, manufacturer reference, included accessories, availability, estimated dispatch date, freight and applicable taxes.
Obtain written warranty terms covering the actual generator supplied, including the warrantor, coverage period, operating territory and any registration or commissioning conditions.
For international enquiries, provide the destination country and required emissions or conformity documents. Confirm that the documentation corresponds to the offered engine and generator build.
Frequently Asked Questions
Is the Fischer Panda 10000 PVK-UK a 10 kW generator?
The published nominal real-power figure is 8.0 kW. Use the applicable electrical specification when sizing the installation.
Why do the documents show both 9.0 and 9.4 kVA?
Fischer Panda UK’s reference PDF lists 9.0 kVA, while the current model pages list 9.4 kVA. Confirm which documentation applies to the offered unit.
Is this a variable-speed inverter generator?
The documented 10000x is a fixed-speed model operating at 3,000 RPM. Fischer Panda’s iSeries is a separate variable-speed range.
Does PVK-UK include a radiator?
The PVK-UK arrangement incorporates its radiator and cooling system. Confirm the supplied cooling assembly and associated controls in the quotation.
How quiet will it be after installation?
Fischer Panda UK publishes 52 dB(A) at 7 metres. Installed noise depends on mounting, surroundings, load and measurement conditions; that reference figure is not a site-specific noise guarantee.
Can I reuse my existing controls and mounts?
Possibly. Supply identification details, photographs and measurements so compatibility can be assessed before those components are retained.
Request Your Fischer Panda FPVG0305 Quotation
For a Fischer Panda 10000 PVK-UK generator for sale, contact Marine Inboard Specialists and quote FPVG0305.
Include the vehicle type, electrical load schedule, required voltage and frequency, daily running hours, mounting measurements and proposed installation position. State how soon you intend to purchase, your required delivery date, and your billing and delivery addresses.
For replacements, attach clear photographs of the existing generator plate, control panel, mounting arrangement and cooling installation.







Reviews
There are no reviews yet.