Fischer Panda 8000i PVK-UK Generator for Sale – FPVG0302
The Fischer Panda 8000i PVK-UK is a two-cylinder diesel vehicle generator with integrated radiator cooling and variable-speed operation. Its identified manufacturer reference supplies 230 V, 50 Hz, single-phase AC power, with a published nominal output of 6.4 kW / 8.0 kVA.
Contact Marine Inboard Specialists under listing reference FPVG0302 for a quotation covering the generator, matched electrical equipment, controls and installation accessories required for your project.
Specification note: The supplied listing states 6.0 kW / 8.0 kVA. The manufacturer’s model-specific datasheet for article 0005537 publishes 6.4 kW / 8.0 kVA. This description uses that identified reference; confirm the actual assembly and its applicable rating when ordering.
Request Price & Availability | Download Manufacturer Datasheet
Integrated Cooling for External Vehicle Installation
PVK-UK identifies an external vehicle generator arrangement with an integrated radiator. Fischer Panda combines the cooling system with a metal enclosure, chassis mounting provisions and service access within the generator package. A separately mounted radiator is therefore unnecessary for this configuration.
The installation still needs adequate cooling airflow, exhaust routing and maintenance clearance. Include the surrounding chassis structure and body panels when assessing radiator air intake and discharge.
Fischer Panda distinguishes PVK-UK from PVK-U, which requires a separate radiator, and PVMV-N, which is intended for internal vehicle installation with remote cooling. Specify a vessel application explicitly if your project requires a marine generator configuration.
Variable-Speed Operation and Matched Controls
The 8000i PVK-UK belongs to Fischer Panda’s iSeries range. Its engine speed adjusts with electrical demand, making the operating load relevant when comparing generator packages.
The referenced assembly uses a Kubota Z482 diesel engine, with two cylinders, 479 cm³ displacement and a 12 V starting system. The generator control is identified as iControl.
Confirm the matched inverter, control-panel version, connecting cables and installation locations in the quotation. Retaining an existing inverter or panel requires a compatibility check by model and part number.
Technical Specifications
The following figures use Fischer Panda’s 8000i PVK-UK datasheet, article 0005537. Match the offered FPVG0302 assembly to its applicable documentation before purchase.
| Specification | Published reference |
|---|---|
| Product listing reference | FPVG0302 |
| Generator model | Fischer Panda 8000i PVK-UK |
| Manufacturer reference article | 0005537 |
| Generator family | iSeries – Perfect Power |
| Application | External vehicle installation |
| Nominal electrical output | 6.4 kW / 8.0 kVA |
| Reference AC voltage / frequency | 230 V / 50 Hz |
| Phase configuration | Single-phase |
| Engine speed in linked datasheet | Variable, 2,200–2,800 RPM |
| Fuel type | Diesel |
| Engine manufacturer / model | Kubota Z482 |
| Cylinders / displacement | 2 / 479 cm³ |
| Starter system | 12 V |
| Control system | iControl |
| Published power factor | 0.80 |
| Capsule designation | MPL 4DS |
| Capsule dimensions, L × W × H | 1,295 × 531 × 621 mm, excluding fittings |
| Published generator weight with capsule | Approximately 265 kg |
| Published sound level | 52 dB(A) at 7 metres |
| Cooling arrangement | Integrated radiator |
| Continuous operating rating | Confirm for the supplied assembly and operating conditions |
Sources: Fischer Panda model datasheet and 2026 vehicle generator brochure. Allow additional space for connections, mounting hardware and servicing.
Documentation differences: The linked datasheet gives 2,200–2,800 RPM, while a separate manufacturer product page lists 2,450–2,950 RPM. Another UK specification sheet describes 6.0 kW / 7.5 kVA. Obtain the rating, speed range, dimensions and weight applicable to the actual unit offered.
Understanding 6.4 kW and 8.0 kVA
Kilowatts describe real electrical power; kilovolt-amperes describe apparent power. For the identified reference, 8.0 kVA × 0.80 = 6.4 kW.
Assess both limits alongside power factor, motor starting demand and simultaneous appliance use. For extended running periods, request the applicable continuous-output rating and operating conditions for the supplied generator and electrical package.
For example, a charger drawing 2.4 kW from the AC supply, a 2.0 kW heater and 1.0 kW of other equipment total 5.4 kW before cooling accessories or a compressor start. This illustrative calculation helps prepare a load schedule; it does not establish suitability by itself.
Is This the Right Generator for Your Vehicle?
Use three checks when planning a new installation or replacement: match the electrical demand, match the mounting space and match the cooling airflow.
Match the Electrical Demand
Provide the equipment that must operate together, its AC input requirements and the intended daily running hours. Include starting-current information for compressors, pumps and other motors where available.
For replacements, send the existing generator’s model, serial number, output, voltage, frequency and phase. Have your installer assess electrical protection, shore-power changeover, charger integration and control compatibility.
Match the Mounting Space
Measure available chassis space, ground clearance and maintenance access. Allow room for connections, cover removal and any separately mounted inverter or control equipment.
Provide photographs of structural supports, existing mounts and connection positions. Request the drawing applicable to the offered assembly before finalising mounting points or vehicle modifications.
Confirm the complete installed weight, including associated electrical equipment, supports and fluids, for the package being offered.
Match the Cooling Airflow
Have the installer assess radiator intake and discharge clearances, nearby obstructions and the risk of heated discharge air returning to the intake. Include the vehicle’s intended ambient conditions and parked operating arrangement.
The published 52 dB(A) at 7 metres is a reference figure. Sound experienced around the vehicle also depends on cooling fans, mounting, structural vibration and surrounding surfaces.
If replacing a generator that overheated, assess the original cooling and airflow problem before commissioning the replacement.
Generator Package and Scope of Supply
Request an itemised quotation identifying the generator assembly, integrated cooling equipment, matched inverter, control panel, cables, fuel connections, mounting components and exhaust installation parts included.
Specify cable lengths, service spares and any existing components you intend to retain. Compatibility should be checked by model and part number.
Identify installation labour, vehicle modifications, commissioning, manuals and documentation separately. This establishes the complete vehicle generator replacement cost and helps you compare quotations accurately.
An integrated radiator describes the cooling arrangement. The written quotation establishes the complete scope of supply.
Compare Fischer Panda Installation Options
For a separate-radiator arrangement, compare the Fischer Panda FPVG0202 8000i PVK-U. Its cooling installation and overall space requirements differ from the integrated PVK-UK package.
Browse the Fischer Panda generator range for other capacities and installation arrangements. Compare the applicable operating rating, electrical configuration and package contents alongside output.
Fischer Panda 8000i PVK-UK Price, Delivery and Warranty
Request a Fischer Panda 8000i PVK-UK price for your required equipment package and delivery destination. The quotation should identify the actual manufacturer article, equipment condition, supplied accessories, current availability, dispatch estimate, freight charges and applicable taxes.
Obtain written warranty terms for the actual generator supplied, including the warrantor, coverage period, territory and any registration or commissioning requirements.
For international orders, specify the destination country and required emissions or conformity documentation so the offer addresses the appropriate configuration and supply documents.
Frequently Asked Questions
Is the Fischer Panda 8000i PVK-UK an 8 kW generator?
The identified manufacturer datasheet publishes 6.4 kW / 8.0 kVA nominal output. The kVA figure should not be treated as its real-power rating.
Why does the FPVG0302 listing state 6.0 kW?
The supplied listing and identified manufacturer reference differ. Have the quotation confirm the actual article number, rating plate and applicable specification.
Does the PVK-UK have an integrated radiator?
Yes. The PVK-UK arrangement incorporates radiator cooling within the external generator package. Installation still needs suitable cooling airflow.
Is it a fixed-speed generator?
It is a variable-speed iSeries model. Confirm the operating range applicable to the supplied assembly, as manufacturer publications give different reference ranges.
What are its reference dimensions and weight?
The identified reference capsule measures 1,295 × 531 × 621 mm, excluding fittings, and has a published weight of approximately 265 kg including the capsule. Allow for installation clearances and separately mounted equipment.
Does the quotation include the inverter and controls?
The itemised quotation establishes the scope. Confirm the matched inverter, control panel, cables, mounts and installation accessories required for the complete package.
Request Your Fischer Panda FPVG0302 Quotation
For a Fischer Panda 8000i PVK-UK generator for sale, contact Marine Inboard Specialists with reference FPVG0302.
Include your vehicle type, electrical load schedule, daily operating hours, available mounting space and proposed installation photographs. State how soon you want to purchase, your required delivery date, and your billing and delivery addresses.
For replacements, attach clear photographs of the existing generator plate, inverter, control panel and mounting arrangement.







Reviews