Description

Fischer Panda 15000i PVMV-N Diesel Inverter Generator for Sale – FPVG0103

The Fischer Panda 15000i PVMV-N is a three-cylinder diesel inverter generator for internal vehicle installation, with published nominal output of 12.0 kW / 15.0 kVA. Listed by Marine Inboard Specialists under reference FPVG0103, it is an option for owners, operators and installers planning an electrical power system for a compatible motorhome or specialist vehicle.

Fischer Panda publishes 230V single-phase and 400V three-phase versions. As the FPVG0103 title does not specify voltage or phase, identify your electrical requirement when enquiring so the quotation can cover the correct generator and inverter package.

PVMV-N Installation with External Radiator Cooling

Fischer Panda classifies PVMV-N within its vehicle-generator range. The 15000i reference incorporates a water-cooled exhaust arrangement and requires an external radiator. The cooling package therefore forms part of the installation design alongside the generator compartment, fuel supply and exhaust route.

Plan radiator location, airflow, hose routing and service access before finalizing the equipment layout. A capsule that fits the compartment still needs an appropriate cooling installation.

For a boat or keel-cooling project, state the intended application at enquiry stage. Have the proposed cooling and exhaust arrangement assessed for the vessel and the exact generator configuration.

230V Single-Phase and 400V Three-Phase Versions

Both published versions carry the 12.0 kW / 15.0 kVA nominal rating, but their electrical configurations and reference engine-speed ranges differ.

Published version Manufacturer article Published engine-speed reference
230V, single-phase, 50Hz 0014733 2,450–2,950 RPM
400V, three-phase, 50Hz 0005514 2,200–2,800 RPM

The listing’s 2,200–2,800 RPM range also appears in earlier iSeries literature. It does not establish voltage or phase by itself. Use the manufacturer article number and supplied documentation to identify the assembly ordered.

For a three-phase installation, provide the connected equipment’s voltage and individual phase loads. The generator’s total rating alone does not establish the permitted loading on one phase; have your installer assess load distribution and the applicable limits.

Technical Specifications

The common reference figures below are supported by Fischer Panda’s 15000i 230V PVMV-N datasheet, its published 400V model information and the 2026 vehicle generator brochure.

Specification Published reference
Product family Fischer Panda 15000i PVMV-N
Marine Inboard Specialists reference FPVG0103
Application Vehicle, internal installation
Generator technology Variable-speed iSeries inverter system
Nominal electrical output 12.0 kW / 15.0 kVA
Electrical options 230V single-phase or 400V three-phase
Frequency 50Hz for the reference versions
Reference power factor 0.8
Engine manufacturer / model Kubota D902
Fuel / cylinders Diesel / three cylinders
Displacement 898 cm³
Engine speed Version dependent; see reference table above
Starter system 12V electric
Control system iControl
Cooling Water-cooled with external radiator
Sound enclosure GFK 4DS
Approximate capsule dimensions 910 × 515 × 619 mm, L × W × H, excluding fittings
Approximate generator weight including capsule 230 kg
Published sound level 54 dB(A) at 7 metres
Inverter and radiator package Identify the supplied models and installation requirements in the quotation

The dimensions describe the capsule. Establish the complete installed space and weight allowance for the radiator, inverter, mountings and connections when planning the project.

Variable-Speed Inverter Power and Continuous Output

The iSeries uses an inverter to regulate the AC supply while engine speed responds to electrical demand. Fischer Panda’s vehicle iSeries brochure describes a sine-wave output intended for applications including computers and communications equipment.

15.0 kVA and 12.0 kW are different electrical measurements. At a power factor of 0.8, 15.0 kVA corresponds to 12.0 kW. Assess both the real-power demand and apparent-power requirement of the equipment being supplied.

Fischer Panda’s September 2019 vehicle iSeries brochure lists 10.8 kW continuous output for the 15000i PVMV-N. Use this as a historical reference and obtain the continuous rating applicable to the exact assembly offered.

As an illustrative calculation, equipment drawing 3.0 kW, 2.5 kW and 2.0 kW totals 7.5 kW. Cooling auxiliaries and other simultaneous loads must also be counted. Compressor and motor starting requirements need a separate assessment of surge capability.

Is This the Right Replacement Generator?

Use three checks when assessing a Fischer Panda vehicle generator replacement: match the electrical supply, match the cooling package and match the installation.

Match the Electrical Supply

Provide the required voltage, frequency and phase arrangement, typical simultaneous loads and expected running hours. Identify equipment with high starting demand.

For a replacement, include the existing generator, inverter and control-panel details. Have your installer establish compatibility with any wiring, monitoring equipment or remote-start controls proposed for reuse.

Match the Cooling Package

Provide the existing radiator model, mounting location, fan supply voltage and cooling-hose arrangement. State the expected operating environment and whether the vehicle will work in hot conditions.

Have the installer assess radiator capacity and airflow for the proposed layout. If the previous generator overheated, include an assessment of the cause in the replacement plan.

Match the Installation

Provide the vehicle make, model and year, available compartment dimensions and photographs of the mounting area. Include the fuel connections, exhaust route, radiator location and access openings.

Allow room for fittings, hoses, cables, mountings, capsule removal and servicing. The generator’s published capsule dimensions alone do not establish a direct replacement fit.

Inverter, Radiator and Scope of Supply

Request an itemized quotation identifying the generator assembly, capsule, matched inverter, control panel, harness, mounting equipment and installation accessories included.

The manufacturer lists radiator options with different mounting arrangements and fan supplies. Establish the selected radiator, fan controls, coolant plumbing and exhaust components for the vehicle layout.

Match the inverter and controls to the generator’s electrical version. Include installation labour, electrical protection, commissioning and any replacement vehicle-side components when comparing the complete project cost.

Retain the manufacturer article number, generator serial number and supplied manuals for future service and parts enquiries. FPVG0103 identifies the listing; the equipment identification establishes the applicable configuration.

Installation Drawing and Sound Levels

Fischer Panda provides a 15000i PVMV-N reference drawing. Your installer should obtain the drawing revision applicable to the supplied assembly when checking mounting positions and connections.

The published reference sound level is 54 dB(A) at 7 metres. Noise experienced inside or near the vehicle also depends on mounting, structural vibration, radiator fans, exhaust routing and compartment construction. Discuss these factors when locating the equipment near sleeping or working areas.

Compare Related Fischer Panda Vehicle Generators

For smaller electrical loads, compare the Fischer Panda 8000i PVMV-N – FPVG0102 and Fischer Panda 5000i PVMV-N – FPVG0101.

Compare continuous output, starting capability, electrical configuration, cooling requirements and package contents. Browse our Fischer Panda generators and identify whether your project is a vehicle or marine installation.

Fischer Panda 15000i PVMV-N Price, Delivery and Warranty

Request a Fischer Panda 15000i PVMV-N price for the electrical version, package and destination required. The quotation should identify the manufacturer article number, equipment condition, scope of supply, availability, dispatch estimate, freight charges and applicable taxes.

Obtain the warranty terms for the actual unit, including the warrantor, coverage period, territory and any registration or commissioning requirements. Provide the operating country and required emissions documentation so the offered assembly can be assessed for the intended application.

Frequently Asked Questions

Is the 15000i PVMV-N a vehicle or marine generator?

Fischer Panda classifies it within its vehicle range for internal installation. State any vessel application separately so the installation and configuration can be assessed.

Is FPVG0103 supplied as 230V or 400V?

The listing title does not specify. Fischer Panda publishes both versions; identify the required voltage and phase arrangement in your enquiry.

Does 15.0 kVA mean 15.0 kW?

No. The published nominal rating is 12.0 kW / 15.0 kVA, corresponding to a power factor of 0.8.

What is the continuous output?

The September 2019 brochure lists 10.8 kW continuous. Confirm the applicable continuous rating for the assembly offered.

Which engine-speed range applies?

The current 230V reference gives 2,450–2,950 RPM; the 400V reference gives 2,200–2,800 RPM. Match the supplied version to its documentation.

Does the installation require an external radiator?

Yes. The published PVMV-N reference requires an external radiator. Establish the radiator and associated equipment in the itemized quotation.

Request Your Fischer Panda 15000i PVMV-N Quotation

For a Fischer Panda 15000i PVMV-N diesel inverter generator for sale, contact Marine Inboard Specialists and quote FPVG0103.

Include your application, vehicle details, required voltage, frequency and phase arrangement, expected loads, installation space and radiator requirements. State how soon you want to purchase, your required delivery date, and your billing and delivery addresses. For a replacement, attach photographs of the existing generator plate, inverter, radiator and installation.

 

Reviews

There are no reviews yet.


Be the first to review “Fischer Panda FPVG0103 – FP Generator 15000i PVMV-N, KW/kVA 12.0 / 15.0, 2200-2800 RPM, 3 Cyl.”